摘要 使用RELAP5对CFETR水冷固态增殖包层的3#包层模块建立模型,并开展了稳态工况和不同破口面积下的真空室内破口事故分析。结果表明,事故发生后真空室压力迅速升高,小破口事故时,向大泄压罐泄压可防止真空室超压;大破口事故时,真空室超压保护系统无法有效地控制压力上升,且增大泄压罐体积以缓解真空室压力的效果不显著。在添加联箱出口止回阀后,可有效防止冷却剂逆向流动进入真空室,使真空室压力维持在安全范围内,不需要启用真空室超压保护系统。 The module #3 of WCCB blanket for CFETR is modeled using RELAP5. Steady-state operation and in-vessel LOCA with different break areas are analyzed. The results indicate that the pressure in the vacuum vessel increases rapidly. In a small-break LOCA, relieving the pressure to the large suppression tank can prevent the vacuum vessel from overpressure after the accident occurs. In a large-break LOCA, the vacuum vessel pressure suppression system(VVPSS) cannot curb the rise in pressure effectively, and the effect is inapparent by increasing the volume of the suppression tanks to reduce the pressure in the vacuum vessel. After the check valves are added on the outlet pipes of manifold, the coolant reverse flow into the vacuum vessel is effectively prevented,so that the pressure in the vacuum vessel is maintained within a safe range without the need to activate the VVPSS.
作者 王文嘉 成晓曼 马学斌 刘松林 WANG Wen-jia;CHENG Xiao-man;MA Xue-bin;LIU Song-lin(Hefei Institutes of Physical Science,Chinese Academy of Sciences,Hefei 230031;University of Science and Technology of China,Hefei 230026;Institute of Energy,Hefei Comprehensive National Science Center,Hefei 230031;Shenzhen University,Shenzhen 518060)
出处 《核聚变与等离子体物理》 CAS CSCD 北大核心 2022年第4期433-439,共7页 Nuclear Fusion and Plasma Physics
基金 国家重点研发计划(2017YFE0300502,2017YFE0300503)。
关键词 CFETR 水冷固态增殖包层 事故安全 真空室内破口 RELAP5 CFETR WCCB blanket Accident safety In-vessel LOCA RELAP5
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部