期刊文献+

Statistical analysis of ocular monochromatic aberrations in Chinese population for adaptive optics ophthalmoscope design

下载PDF
导出
摘要 It is necessary to know the distribution of the Chinese eye's aberrations in clinical environment to guide high-resolution retinal imaging system design for large Chinese population application.We collected the monochromatic wave aberration of 332 healthy eyes and 344 diseased eyes in Chinese population across a 6.0-mm pupil.The aberration statistics of Chinese eyes including healthy eyes and diseased eyes were analyzed,and some differences of aberrations between the Chinese and European race were concluded.On this basis,the requirement for adaptive optics(AO)correction of the Chinese eye's monochromatic aberrations was analyzed.The result showed that a stroke of 20μm and ability to correct aberrations up to the 8th Zernike order were needed for reflective wavefront correctors to achieve near difraction-limited imaging in both groups for a reference wavelength of 550 nm and a pupil diameter of 6.0mm.To verify the:analysis mentioned above,an A0 floodillumination system was established,and high-resolution retinal imaging in vivo was achieved for Chinese eye including both healthy and diseased eyes.
出处 《Journal of Innovative Optical Health Sciences》 SCIE EI CAS 2017年第1期84-93,共10页 创新光学健康科学杂志(英文)
基金 the National.Key Scientific Instrument and Equipment Devel-opment Project(Grant Nos.2012YQ120080 and 2013YQ49085903) the National Natural Science.Foundation of China(Grant No.61378064)lthe National High Technology Research and Development Program of China(Grant No.2015AA020510).
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部