摘要
为进一步评估周边对流层延迟,本文基于中国境内以及周边5个MGEX跟踪站,对比分析BDS-3及与BDS-3兼容频率组合静态精密单点定位精度以及评估对流层延迟结果。实验结果表明,双系统组合能有效改善卫星状况,BDS-3以及其他情况静态精密单点定位水平精度优于1.5 cm,高程定位精度优于3 cm,评估对流层延迟结果较好,JFNG站评估对流层延迟结果误差在1 cm以内,其余测站评估对流层延迟结果误差在1—2 cm之间。
In order to further evaluate the surrounding tropospheric delay,this paper compares and analyzes the static precision single-point positioning accuracy of BDS-3 and BDS-3 compatible frequency combination based on 5 domestic and foreign MGEX tracking stations,and evaluates the results of tropospheric delay.The experimental results show that the dual system combination can effectively improve the satellite status.The static precision single-point positioning accuracy of BDS-3 and other situations is better than 1.5 cm,and the altitude positioning accuracy is better than 3 cm.The evaluation result of tropospheric delay is good.JFNG station evaluates tropospheric delay,and the error of the result is within 1 cm.The error of the tropospheric delay evaluated by other stations is between 1 and 2 cm.
作者
李彬彬
王笑
秦海超
LI Binbin;WANG Xiao;QIN Haichao(Xiong′an Academy of Urban Planning and Design,Co.,Ltd.,Rongcheng 071700,China;Comprehensive Institute of Geotechnical Investigation and Surveying,Co.,Ltd.,Beijing 100007,China)
出处
《测绘与空间地理信息》
2023年第1期118-121,共4页
Geomatics & Spatial Information Technology