摘要 冷泵是PVD设备重要的组成部分,主要负责保持腔室内的真空环境,它利用高纯度氦气的压缩膨胀循环来达到冷板低温,通过低温冷板捕捉腔室内的气体达到高真空度的环境。若冷泵出现故障,将直接影响腔室内的真空度,间接地影响晶圆的加工质量;本文主要介绍由于氦气纯度低导致冷泵异响的一种分析方法。 The cold pump is an important part of PVD equipment.It is mainly responsible for maintaining the vacuum environment in the chamber.It uses the compression and expansion cycle of high-purity helium gas to achieve the low temperature of the cold plate,and captures the gas in the chamber through the low temperature cold plate to achieve high vacuum degree.environment of.If the cold pump fails,it will directly affect the vacuum degree in the chamber and indirectly affect the processing quality of the wafer.This article mainly introduces an analysis method for the abnormal noise of the cold pump caused by the low purity of helium.
作者 武学伟 刘春光 李伯 WU Xue-wei;LIU Chun-guang;LI Bo(Beijing NAURA Microelectronics Equipment Co.,Ltd.,Beijing 100176,China;Aircraft Maintenance and Engineering Corporation,Beijing 100621,China)
出处 《价值工程》 2023年第3期94-96,共3页 Value Engineering
关键词 冷泵 PVD设备 氦气纯度 冷泵异响 cold pump PVD equipment helium purity abnormal noise of cold pump