期刊文献+

永久起搏器植入术后囊袋破溃自行拔除电极一例

原文传递
导出
摘要 77岁,男性,因“发现起搏器囊袋变薄并破溃半月”入院,3年前患者因三度房室传导阻滞,经左侧锁骨下静脉安装永久起搏器;入院前3个月曾发生过急性脑梗死,治疗后好转。入院后给予抗感染、囊袋清创术及对症治疗。后患者突发躁狂,自行拔除起搏器电极置于体外,未出现严重并发症,病情稳定后经右侧锁骨下静脉再次安装永久起搏器。术后3月余再次发生囊袋感染,因房室传导阻滞改善,心率波动于40~50次/分,最终彻底移除起搏器。
出处 《中国心脏起搏与心电生理杂志》 2022年第6期579-580,共2页 Chinese Journal of Cardiac Pacing and Electrophysiology
  • 相关文献

参考文献2

二级参考文献10

  • 1Love C J, Wilkoff BL, Byrd CL et al. Recommendations for extraction of chronically implanted transvenous pacing and defibrillator leads: indications, facilities, training. North American Society of Pacing and Electrophysiology Lead Extraction Conference Faculty. Pacing Clin Electrophysiol, 2000;23:544.
  • 2Darouiche RO. Trealment of infections ass iated with surgical implants. N Engl J Med, 2004;350:1422.
  • 3Baddour LM, Epstein AE, Erickson CC et al. Update on cardiovascular implantahle electronic device infections and their management: a scientific statement from the American Heart Association. Circulation, 2010;121:458.
  • 4Wilkoff BL, Love C J, Byrd CLet al. Transvenous lead extraction: Heart Rhythm S icty expert consensus on facilities, training, indications, and patient management: this document was endorsed by the American Heart Association (AHA). Heart Rhythm, 2009;6:1085.
  • 5Greenspon AJ, Patel JD, Lau E et al. 16-year trends in the infection burden for pacemakers and implantable cardi 111 the United States 1993 to 2008. J Am Coil Cardiol, 2011;58:1001.
  • 6S.M. Kurtz, J.A. Ochoa, E. Lau et al.Implantation trends and patient profiles for pacemakers and implantable cardioverter defibrillators in the United States: 1993-2006.Pacing Clin Electrophysiol, 2011;33: 705.
  • 7Arnold J. Greenspon, Jasmine D. Patel, Edmund Lau et al. Trends in Permanent Pacemaker Implantation in the United States From 1993 to 2009: Increasing Complexity of Patients and Procedures. J Am Coil Cardiol,60:1540.
  • 8S.M. Kurtz, J.A. Ochoa, E. Lau et al.Implantation trends and patient profiles for pacemakers and implantable cardioverter defibrillators in the United States: 1992-2006. Paeing Clin Electrophysiol, 33:705.
  • 9Voigt A, Shalaby A, Saba S. Rising tales of cardiac rhythm management device infections in the United States: 1996 through 2003. J Am Coil Cardiol, 2000;48:590.
  • 10Klug D, Balde M, Pavin D et al. Risk factors related to infections of implanted p emakers and cardioverter-defibrillators: results of a large prospective study. Circulation, 116:1349.

共引文献82

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部