摘要
This paper selected Manyuan Village in Oliver Plain(Ganlanba) as a case study to analyze the climate adaptation of traditional villages in Xishuangbanna Dai Autonomous Prefecture with high temperature and high humidity. Three main thermal environment elements, i.e., temperature, humidity, and wind speed, were collected for comfort evaluation through Kriging analysis and UTCI equivalent temperature calculation. The research concluded the characteristics of the climate adaptation and the spatial factors affecting the comfort degree of traditional Dai villages, including mountain, vegetation, water body, pavilion and corridor, and underlying surface. Finally, the authors also discussed the spatial optimization proposals to improve the comfort degree of traditional Dai villages.
作者
Cheng Haifan
Chen Peng
Hu Rong
程海帆;陈鹏;胡荣(Faculty of Architecture and City Planning,Kunming University of Science and Technology,Kunming,P.R.China;Kunming Maipu Space Technology Ltd.,Kunming,P.R.China)
基金
funded by the National Key Technologies R&D Program:Comprehensive Demonstration of Disaster Prevention and Mitigation Technology for Ethnic Villages in Southwest China(2020YFD1100705)
National Natural Science Foundation of China:Genealogical Study on the Revitalization of Traditional Settlements Along the Tea Horse Road in Yunnan and Tibet in the Perspective of Spatio-Temporal Continuity(51968029)
National Natural Science Foundation of China for Youth Science Fund:Methods for Identifying Spatial Planning of Ecological Rehabilitation by Integrating Ecosystem Services and Stakeholders’Well-Being(42101269)。