摘要 文章根据典型光伏发电接入系统无功产生的特点,分析常规自发自用分布式光伏电站中无功补偿装置不能自动实施补偿问题的产生原因,确定无功补偿装置的有效接入方式,并提出分布式光伏接入整体补偿方案。 According to the characteristics of reactive power generation in the typical photovoltaic power generation access system,this document analyzes the causes of the reactive power compensation device cannot automatically implement the compensation in the conventional self-use distributed photovoltaic power stations,determines the effective access mode of the reactive power compensation device,and proposes the overall compensation scheme of distributed photovoltaic access.
作者 杨秦川 于湛瑶 李荣江 Yang Qin-chuan;Yu Zhan-yao;Li Rong-jiang
出处 《电力系统装备》 2022年第12期178-180,共3页 Electric Power System Equipment
关键词 光伏 无功补偿 电流采样 功率因数 photovoltaic reactive power compensation current sampling power factor