摘要 通过能量路由器对传统配电台区进行柔性化改造,能够有效应对冲击性负荷与分布式电源接入台区所带来的影响。提出一种多端口能量路由器优化配置方法,能够合理配置能量路由器中储能单元容量,以使台区固定资产投资、设备电能损耗及负荷限幅损失构成的综合成本最小。首先,简要介绍了多端口能量路由器及其优势;然后,以配电台区投资运营综合成本最小为目标函数,建立了考虑储能寿命约束的多端口能量路由器的优化配置模型;最后,通过算例验证了多端口能量路由器在交直流多模式供电、源荷储高效互动与设备柔性增容方面的显著优势。 The flexible transformation of the traditional distribution station area through the energy router can effectively deal with the impact of shock load and distributed power access to the station area. Therefore, this paper proposes a multi-port energy router optimization configuration method, which can reasonably configure the capacity of the energy storage unit in the energy router, so as to minimize the comprehensive cost of the fixed asset investment, equipment power loss and load limiting loss. Firstly, the paper briefly introduces the multi-port energy router and its advantages;Then, taking the comprehensive cost of investment and operation in the distribution station area as the objective function, the optimal configuration model of multi-port energy router considering the constraint of energy storage life is established;Finally, the significant advantages of multi-port energy router in AC/DC multi-mode power supply, efficient interaction between source load and storage and flexible capacity expansion of equipment are verified by numerical examples.
作者 陈斌 李昀宸 马仲坤 刘文龙 吕志鹏 黄奇峰 金荣康 戚星宇 CHEN Bin;LI Yunchen;MA Zhongkun;LIU Wenlong;LÜ Zhipeng;HUANG Qifeng;JIN Rongkang;QI Xingyu(Changzhou Power Supply Branch of State Grid Jiangsu Electric Power Co.,Ltd.,Changzhou 213003,China;College of Automation Engineering,Nanjing University of Aeronautics and Astronautics,Nanjing 210016,China;State Grid Shanghai Energy Interconnection Research Institute Co.,Ltd.,Shanghai 201210,China;Shanghai University of Electric Power,Shanghai 201306,China)
出处 《供用电》 2023年第2期32-38,共7页 Distribution & Utilization
基金 国网江苏省电力有限公司科技项目(J2021025)。
关键词 配电台区 能量路由器 容量配置 交直流混合供电 储能单元控制 distribution station area energy router capacity configuration AC/DC mixed power supply energy storage unit control
  • 相关文献

参考文献20

二级参考文献335

共引文献634

同被引文献43

引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部