摘要 为了解决传统箱形截面柱法兰连接节点对结构空间占用的问题,提出了一种箱形截面柱剪力键式全螺栓连接节点,并对2个全螺栓连接箱形截面柱和1个整体式箱形截面柱进行拟静力试验研究。观察了全螺栓连接箱形截面柱的破坏现象,分析了全螺栓连接箱形柱的滞回性能、承载力、刚度退化、延性以及耗能能力等受力特性。结果表明:整体式箱形截面柱和剪力键式全螺栓连接箱形截面柱均发生塑性铰破坏;滞回曲线饱满,具有良好耗能能力;剪力键和水平单向螺栓的设置可使全螺栓连接箱形截面柱承载力提高24.64%,竖向高强螺栓拉力降低29.44%;节点处钢连接件的设置约束了箱形截面柱的屈曲变形,与整体式箱形截面柱相比,全螺栓连接箱形截面柱的位移延性系数提高了26.47%;钢连接件间无滑移,剪力键式全螺栓连接节点连接可靠。通过剪力键式全螺栓连接节点与刚接节点有限元分析结果对比,表明在工程应用中箱形截面柱剪力键式全螺栓连接节点可等效刚接。采用GB 50011—2010《建筑抗震设计规范》对箱形截面柱剪力键式全螺栓连接节点进行承载力验算,计算结果与试验结果吻合。 In order to solve the problem of occupying significant structural space of the traditional box-shaped cross section column flange connection joints, a box-shaped cross section column connection incorporating shear key and bolts was proposed in this paper, and two bolted connection box-shaped cross section column and one integral box-shaped cross section column specimens were studied by quasi-static tests. The failure phenomenon of the bolted connection box-shaped cross section column was observed, and the mechanical properties, such as hysteretic behavior, bearing capacity, stiffness degradation, ductility and energy dissipation capacity of the bolted connection box-shaped cross section column, were analyzed. The results show that: the integral box-shaped cross section column and the box-shaped cross section column connection incorporating shear key and bolts both exhibit column hinge failure. The hysteresis curve is full and has good energy dissipation capacity. The shear key can increase the bearing capacity of the bolted connection box-shaped cross section column by 24.64% and reduce the bolt tensile force by 29.44%. The steel connector at the joint restrains the buckling deformation of the box-shaped cross section column, and the ductility is increased by 26.47%. There is no slip between the steel connectors, and the joint is reliable. The numerical analysis results show that the bolts joint can be equivalently considered as rigid connections in engineering applications. Code GB 50011—2010 ‘Code for seismic design of buildings’ is used to check the bearing capacity of the joints, and the calculation results are consistent with the test results.
作者 郝家树 任庆英 张锡治 刘文珽 张晓萌 张音玄 HAO Jiashu;REN Qingying;ZHANG Xizhi;LIU Wenting;ZHANG Xiaomeng;ZHANG Yinxian(School of Civil Engineering,Tianjin University,Tianjin 300072,China;China Architecture Design&Research Group,Beijing 100044,China;Tianjin University Research Institute of Architectural Design and Urban Planning Co.,Ltd,Tianjin 300072,China;Key Laboratory of Coast Civil Structure Safety of the Ministry of Education,Tianjin University,Tianjin 300072,China)
出处 《建筑结构学报》 EI CAS CSCD 北大核心 2023年第1期110-120,共11页 Journal of Building Structures
基金 “十三五”国家重点研发计划项目(2018YFF0300300)。
关键词 箱形截面柱 剪力键 全螺栓连接 拟静力试验 数值模拟 抗震性能 box-sharped cross section column shear key all bolt connection quasi-static test numerical simulation seismic behavior
  • 相关文献

参考文献15

二级参考文献114

共引文献182

同被引文献30

引证文献5

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部