期刊文献+

阳树脂再生度不足导致汽水化学在线仪表异常分析

Analysis of Insufficient Cation Resin Regeneration Degree Leading to Vapor Water Chemistry on-line Instrument abnormality
下载PDF
导出
摘要 着重阐述了某燃机电厂的水汽在线监督电导率表的阳树脂再生度不足,不仅降低了树脂交换容量,同时影响了仪表测量的准确性。通过重新校验工作误差大的电导率表,及时更换树脂的措施解决了这个问题。 It focuses on the insufficient cation resin regeneration degree of the vapor water on-line monitoring conductivity meter in a gas turbine power plant,which not only reduces the resin exchange capacity,but also affects the accuracy of the meter measurement.Through recalibrating the conductivity meter with large operating error,it solves this problemby replacing the resin in time.
作者 李合友 LI Heyou(Guoneng Zhejiang Yuyao Gas Power Generation Co.,Ltd.,Yuyao,Zhejiang 315400,China)
出处 《东北电力技术》 2023年第1期48-50,共3页 Northeast Electric Power Technology
关键词 水汽在线监督系统 电导率表 阳树脂 再生度 树脂交换容量 vapor water on-line monitoring system conductivity meter cation resin regeneration degree resin exchange capacity
  • 相关文献

参考文献5

二级参考文献20

  • 1周仲康,郑敏聪,杨浩,金浩,李建华,孙玉忠,韩永霞.凝结水精处理混床周期制水量偏低原因分析及处理[J].热力发电,2013,42(11):169-171. 被引量:10
  • 2曹杰玉,张昔国,刘玮.电厂电导率表在线检验技术的研究与应用[J].热力发电,2006,35(12):49-51. 被引量:9
  • 3Galster. H. pH Measurement [ J ]. Weinheim Germany VCH, 1991, Table 1 -7.
  • 4Philadelphia, Pa. American Society for Testing and Materials [J]. 1995 Annual Book of ASTM Standards, 1995, Section 11, Volume 11. 1.
  • 5D. Midgley. Assessment of Reference Electrodes for Use in Determining the pH of Acidic, Poorly-Buffered Waters [ J ]. Atmospheric Environment, 1987, 21 (1), 173 - 177.
  • 6李培元主编.火力发电厂水处理级水质控制[M].北京:中国电力出版社,2008.
  • 7GBTl2145--2008.火力发电机组及蒸汽动力设备水汽质量[s].
  • 8DL/T805.2-2004.火电厂汽水化学导则(第2部分:锅炉炉水磷酸盐处理)[s].
  • 9DL/TS05.4--2004.火电厂汽水化学导则(第4部分:锅炉给水处理)[S].
  • 10国家环保局《水和废水监测分析方法》编委会编,魏复盛.水和废水监测分析方法[M]中国环境科学出版社,1997.