期刊文献+

某亚临界机组锅炉分隔屏过热器爆管原因 被引量:2

Causes of tube bursting of boiler division panel superheater in a subcritical unit
下载PDF
导出
摘要 某亚临界机组锅炉分隔屏过热器在运行过程中发生爆管泄漏,采用宏观观察、壁厚测量、化学成分分析、拉伸试验、硬度测试、金相检验、扫描电镜及能谱分析等方法对其爆管原因进行分析。结果表明:分隔屏过热器受热面管受到吹灰蒸汽等冲刷作用,使过热器管局部出现了严重的冲刷磨损减薄,最终导致管子承压能力不足而发生局部破裂。 Tube explosion and leakage occurred in the boiler division panel superheater of a subcritical unit during operation. The causes of tube explosion were analyzed by means of macroscopic observation, wall thickness measurement, chemical composition analysis, tensile test, hardness test, metallographic examination, scanning electron microscope and energy spectrum analysis. The results show that the heating surface tube of division panel superheater was scoured by soot blowing steam, resulting in severe erosion wear and thinning of the superheater tube, which eventually led to insufficient pressure bearing capacity of the tube and local rupture.
作者 龚秋文 刘课秀 马括 封小亮 GONG Qiuwen;LIU Kexiu;MA Kuo;FENG Xiaoiang(Guangzhou Special Pressure Equipment Inspection and Research Institution,Guangzhou 510663,China)
出处 《理化检验(物理分册)》 CAS 2022年第12期68-72,共5页 Physical Testing and Chemical Analysis(Part A:Physical Testing)
关键词 分隔屏过热器 爆管 冲刷 泄漏 division panel superheater tube explosion erosion leakage
  • 相关文献

参考文献7

二级参考文献27

共引文献24

同被引文献16

引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部