摘要
目的探讨时间-空间关联成像(STIC)结合Vocal模式、M型模式对辅助生殖技术(ART)受孕胎儿右心功能的评估作用。方法选择2015年1月至2021年5月于赣州市人民医院超声科进行产前超声检查的孕22^(+0)周至26^(+5)周的ART单胎儿51例,自然受孕胎儿(SP)59例,运用多普勒及STICVocal、STIC-M测得三尖瓣E峰、A峰、E/A值、右心室舒张末期容积(RVEDV),右心室收缩末期容积(RVESV),右心室每搏输出量(RVSV),右心室射血分数(RVEF),三尖瓣环位移(TAPSE),并进行重复性检验,比较两组差异及分析ART心功能与孕周、体重的关系。结果ART胎儿RVSV、RVEF、TAPSE明显低于SP胎儿(P<0.05),而RVEDV、RVESV、三尖瓣E峰、A峰、E/A值两者之间无明显差异(P>0.05)。ART胎儿RVEDV、RVSV、TAPSE与孕周具有相关性(P<0.05),RVEDV、RVSV与体重具有相关性(P<0.05),SP胎儿RVEF、TAPSE与孕周具有相关性(P<0.05),呈正相关。STIC Vocal模式、M型模式下RVEDV、RVESV、TAPSE均具有较高的重复性(P<0.05),且TPASE更为显著。结论STIC技术联合Vocal模式、M超模式可客观的反映ART胎儿右心功能的情况(尤其是TAPSE),可靠、重复性强,可作为评估ART胎儿右心功能的新方法,为临床早期发现ART胎儿右心功能异常提供依据。
Objective To discuss the assessment effect of patio-temporal image correlation(STIC)combined with Vocal mode(STIC-Vocal mode)and M-type ultrasound mode(STIC-M mode)on right heart function in fetuses conceived by assisted reproductive technology(ART).Methods ART fetuses(ART group,n=51)conceived from 22^(+0) weeks to 26^(+5) weeks and fetuses of spontaneous pregnancy(SP group,n=59)with prenatal ultrasonographic examination were chosen from Department of Ultrasound in People’s Hospital of Ganzhou City from Jan.2015 to May 2021.The indexes of tricuspid peak E,peak A and ratio of peak E to peak A(E/A),right ventricular enddiastolic volume(RVEDV),right ventricular end-systolic volume(RVESV),right ventricular stroke volume(RVSV),right ventricular ejection fraction(RVEF)and tricuspid annulus plane systolic excursion(TAPSE)were detected by using color Doppler echocardiogram,STIC-Vocal mode and STIC-M mode.A repeatability test was conducted,and differences were compared between 2 groups.The relationship among heart function of ART fetuses,gestational weeks and body weight was analyzed.Results The indexes of RVSV,RVEF and TAPSE were significantly lower(P<0.05)in ART group than those in SP group,and RVEDV,RVESV,and tricuspid peak E,peak A and E/A had no significant differences(P>0.05)between 2 groups.RVEDV,RVSV and TAPSE were correlated to gestational weeks(P<0.05)and RVEDV and RVSV were correlated to body weight(P<0.05)in ART group,and RVEF and APSE were correlated to gestational weeks in SP group(P<0.05).RVEDV,RVESV and TAPSE had higher repeatability in STIC-Vocal mode and STIC-M mode(P<0.05),and TPASE repeatability was more significant.Conclusion STICVocal mode and STIC-M mode can objectively reflect the right heart function(especially TAPSE)in ART fetuses and they are reliable with a higher repeatability,and they can be used as a new method to review right heart function in ART fetuses and provide evidence for early clinical detection of abnormal right heart function.
作者
杨洁
黄志平
刘敏
宋燕
林霖
黄智华
Yang Jie;Huang Zhiping;Liu Min;Song Yan;Lin Lin;Huang Zhihua(Department of Ultrasound,People's Hospital of Ganzhou City,Ganzhou 341000,China;不详)
出处
《中国循证心血管医学杂志》
2022年第11期1362-1365,共4页
Chinese Journal of Evidence-Based Cardiovascular Medicine
基金
江西省赣州市指导性科技计划课题(GZ2016ZSF074)。
关键词
时间-空间关联成像
辅助生殖技术
胎儿
心功能
Spatio-temporal image correlation
Assisted reproductive technology
Fetuses
Heart function