期刊文献+

红外分光光度法检测西甲硅油中二氧化硅的含量 被引量:1

Determination of Silica in Simethicone by Infrared Spectrophotometry
下载PDF
导出
摘要 目的使用红外分光光度计对西甲硅油中二氧化硅的含量进行检测。方法用0.1 mm溴化钾吸收池,照红外分光光度法测定,扫描次数4,扫描分辨率4 cm^(-1),扫描范围从1335~1040 cm^(-1),读取二甲硅油溶液1250~1150 cm^(-1)波长范围内的最小吸收波长(约1214 cm^(-1)),然后测定西甲硅油对照品溶液与供试品溶液在上述最小吸收波长(约1214 cm^(-1))处的吸光度。结果在该检测条件下,西甲硅油中二氧化硅含量在0.1502~0.4503 g/ml范围内,线性回归方程为y=1.1169x-0.0825,r为0.9994,平均回收率为102.4%,专属性高,精密度和耐用性良好,溶液稳定性好。结论该方法专属性强、准确度高、精密度好、操作简便、用时短,可用于西甲硅油中二氧化硅的含量测定。 Objective To detect the content of silica in simethicone by infrared spectrophotometer.Methods The content of silica in simethicone was determined by infrared spectrophotometry with a 0.1 mm potassium bromide absorption cell.The number of scans was 4,the scan resolution was 4 cm^(-1)and the scanning range was 1335^(-1)040 cm^(-1).The minimum absorption wavelength(about 1214 cm^(-1))of the simethicone solution was read in the wavelength range of1250-1150 cm^(-1),and the absorbance of the simethicone reference solution and the test solution was measured at the above-mentioned minimum absorption wavelength(about 1214 cm^(-1)).Results Under the detection conditions,the linear regression equation of silica was y=1.1169x-0.0825 and the correlation coefficient(r)was 0.9994.The average recovery was 102.4%.The specificity,precision and durability were good and the solution was stable.Conclusion With good specificity and precision,the method is simple and fast,so it can be used for the determination of silica in simethicone.
作者 毕红娜 于晓燕 解春文 侯迪旭 BI Hong-na;YU Xiao-yan;XIE Chun-wen;HOU Di-xu(Shandong Dayin Marine Bio-pharmaceutical Co.,Ltd.,Weihai 264300,China)
出处 《食品与药品》 CAS 2023年第1期69-71,共3页 Food and Drug
关键词 西甲硅油 二氧化硅 红外分光光度法 含量 simethicone silica infrared spectrophotometry content
  • 相关文献

参考文献3

二级参考文献25

共引文献13

同被引文献374

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部