摘要 在数据中心快速发展的背景下,提出一种UPS蓄电池监测方案。该方案将监测系统分为数据采集、数据传输和远程管理3个部分,可以用于蓄电池的运行状态监测、SOC估计、故障预警等功能,结合数据中心运行管理系统,大大提高了数据中心现场的维护与管理效率,为数据中心的稳定运行提供了保障。 Under the background of rapid development of data center, proposes a UPS battery monitoring scheme. The scheme divides the monitoring system into three parts: data acquisition, data transmission and remote management, which can be used for battery operation status monitoring, SOC estimation, fault warning and other functions. Combined with the operation management system of the data center, it greatly improves the maintenance and management efficiency of the data center site, and provides a guarantee for the stable operation of the data center.
作者 丰佳 陈子晗 张立志 宋文 Feng Jia;Chen Zihan;Zhang Lizhi;Song Wen(NARI Technology Nanjing Control Systems Co.,Ltd.,Nanjing,China)
出处 《科学技术创新》 2023年第2期107-110,共4页 Scientific and Technological Innovation
基金 数据中心管理操作系统与规划仿真技术研究(524609210130)。