摘要 针对水电站输电线路发生故障后无法准确实施定位的问题,从行波的实际传播理论出发,推导出一种与波速无关的改进双端定位算法。利用变分模态分解(VMD)能自适应地分解故障电流行波信号,Teager能量算子(TEO)可快速追踪信号的能量变化、运算量小的独特优势,建立了基于VMD-TEO的220 kV输电线路行波定位模型,该模型无需考虑波速修正和双端时间同步。PSCAD仿真结果表明,改进的双端故障定位模型误差百分比最大为0.239%,优于其他定位算法,验证了所提方法的可靠性和优越性。 Aiming at the inability to accurately locate the fault of the transmission line in hydropower station, an improved double-end location algorithm independent of wave velocity was derived from the actual propagation theory of traveling waves. Using the unique advantages of variational mode decomposition(VMD) which can adaptively decompose fault current traveling wave signals, and the Teager energy operator(TEO) which can quickly track the energy change of signals and has less computation, a traveling wave positioning model for 220 kV transmission lines based on VMD-TEO was established. The model does not need to consider wave velocity correction and double terminal time synchronization. The simulation results of PSCAD show that the maximum error percentage of the improved double-end fault location model is 0.239%, which is superior to other location algorithms. The reliability and superiority of the proposed method were verified.
作者 文中 罗苏新 刘斐 郭俊康 郑连华 WEN Zhong;LUO Su-xin;LIU Fei;GUO Jun-kang;ZHENG Lian-hua(College of Electrical Engineering and New Energy, China Three Gorges University,Yichang 443002,China;Hubei Provincial Engineering Technology Research Center for Power Transmission Line,China Three Gorges University,Yichang 443002,China)
出处 《水电能源科学》 北大核心 2023年第1期198-201,166,共5页 Water Resources and Power
基金 国家自然科学基金项目(51807110)。
关键词 水电站 故障定位 双端法 波速修正 能量算子 hydropower station fault location dual-end method wave speed correction energy operator
  • 相关文献

参考文献11

二级参考文献135

共引文献197

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部