摘要
基于以家庭为中心的产科监护模式,提出了家庭式产房的电气设计理念:家庭式产房可以视为一个复合的护理单元,电气设计要从时间和空间两个维度进行考虑。分析比较了家庭式产房的配电方案,阐述了相关照明设计、插座设计和安全防护措施。
Based on family-centered maternity care, the concept of electrical design for LDRP is presented, that LDRP is regarded as a multi-function nursing unit, so the electrical design should be considered from two dimensions of time and space.The power distribution schemes of LDRP are analyzed and compared.The lighting design, socket design and safety protection measures are described.
作者
李沛岩
陆璐
刘富鹏
LI Peiyan;LU Lu;LIU Fupeng(ARTS Group Co.,Ltd.,Suzhou 215000,China;ASIA-PACIFIC Institute of Construction SCITECH Information Co.,Ltd.,Beijing 100044,China)
出处
《现代建筑电气》
2023年第1期23-28,共6页
Modern Architecture Electric
关键词
家庭式产房
以家庭为中心的产科监护模式
负荷分级
产房电气设计
labor-delivery-recovery-postpartum room
family-centered maternity care
load classification
electrical design of delivery room