摘要
为了响应节约数据中心建设成本和运维简便化的需求,基于成组运行设备集中配置ATS理念和N-1原则,提出改进的A级数据中心制冷系统配电方案。该方案可以大幅减少配电室低压柜的出线开关、末端配电柜和电缆,有效降低配电系统的建设成本,同时也减少运维工作量。该改进方案对同类工程建设具有一定借鉴意义。
In response to the demand of saving the construction cost and simplifying the operation, based on the concept of centralized ATS and N-1 principle, this paper proposes an improved power distribution scheme for the refrigeration system of the A-level data center.By adopting this scheme, the outgoing switch, terminal distribution cabinet and cable can be greatly reduced, the construction cost of the system can be effectively decreased, and the operation and maintenance workload can also be cut down.The improvement scheme has certain reference significance for similar projects.
作者
朱发熙
ZHU Faxi(Jiangsu Post and Telecommunication Planning and Design Institute Co.,Ltd.,Nanjing 210019,China)
出处
《现代建筑电气》
2023年第1期58-65,共8页
Modern Architecture Electric
关键词
A级数据中心
制冷系统
配电方案
单点故障
class A data center
cooling system
power distribution scheme
single point of failure