期刊文献+

基于Kirkpatrick-Baez显微镜的芯部自发光成像诊断不确定度评估

Uncertainty evaluate of core symmetry which observed by Kirkpatrick-Baez microscope
下载PDF
导出
摘要 具备高分辨能力(约5μm)的Kirkpatrick-Baez(KB)显微镜大幅提升了芯部自发光诊断图像的空间分辨率,准确评估诊断不确定度有利于开展内爆对称性调谐,提高内爆性能。建立了针对KB显微镜的在线不确定度评估方法,详细分析了其在线背光照相实验中的图像分辨率和噪声,并对内爆物理实验中的芯部自发光数据进行了不确定度评估。结果显示,芯部自发光P2不确定度为6%,P4不对称性的不确定度为8%,满足了现阶段内爆物理实验的诊断需求。 The core emission was observed by Kirkpatrick-Baez(KB)microscope with about 5μm space resolution.It is important to evaluate the uncertainty of core image thus to tune the implosion asymmetry.This article evaluates the spatial resolution and SNR of the backlight image got by KB microscope in the experiment,and calculates the uncertainty for the Legendre moments of core emission.The results show that the uncertainty of P2 is about 6%that of and P4 is about 8%.
作者 蒋炜 董云松 张兴 尹传盛 孙传奎 董建军 尚万里 Jiang Wei;Dong Yunsong;Zhang Xing;Yin Chuansheng;Sun Chuankui;Dong Jianjun;Shang Wanli(University of Science and Technology of China,Hefei 230026,China;Laser Fusion Research Center,CAEP,Mianyang 621900,China)
出处 《强激光与粒子束》 CAS CSCD 北大核心 2023年第3期39-43,共5页 High Power Laser and Particle Beams
基金 国家自然科学基金项目(12075219) 中物院创新基金项目(CX20210019)。
关键词 ICF 内爆不对称性 KB显微镜 不确定度 ICF ignition asymmetry Kirkpatrick-Baez microscope uncertainty
  • 相关文献

参考文献3

二级参考文献38

  • 1Koch J A, Landen O L, Jr Barbee T W, et al. High-energy X-ray microscopy techniques for laser-fusion plasma research at the National Ignition Facility[J].Applied Optics, 1998, 37(10) : 1784-1795.
  • 2Meyerhofer D D. Diagnostics for high-energy-density physics[R].Los Angeles: University of California, 2009.
  • 3Drake R P. Introduction to high energy density physics (HEDP)[G]. Los Angeles: Summer School on High Energy Density Physics. 2009.
  • 4Oertel J A, Archuleta T N, Schrank L S. The large format X ray imager[J]. Review of Scientific Instruments. 2001. 72(1) :701-704.
  • 5Kimbrough J R, Bell P M. Christianson G B. et al. National Ignition Facility core X-ray streak camers[J].Review of Scientific Instruments,2001,72(1):748-750.
  • 6Hilsabeek T J, Hares J D, Kilkenny J D, et al. Pulse-dilation enhanced gated optical imager with 5 ps resolution[J]. Reviewof Scientific Instruments, 2010, 81:10E317.
  • 7Kilkenny J D. The role of experimental science in ICF examples from X-ray diagnoslics and targets[J]. European Physical Journal D,2007, 44(2):289-292.
  • 8Schneider M B, Holder J P, James D I., et al. Time resolved soft X-ray imaging (SXRI) diagnostic for use at the NIF and OMEGA lasers [C]//16th Topical Conference on High Temperature Plasma Diagnostics. 2006.
  • 9Stafford D. Time integrated soft X-ray imaging in high intensity laser experiments[D]. Davis: University of California at Davis, 2009.