摘要
介绍了体育馆冷热源、供暖空调水系统、空调风系统及防冻系统设计等。结合建筑使用特点及当地干热气候特征,采用间接蒸发冷水机组提供高温冷水供比赛大厅座椅送风组合式空调机组预冷段及地面辐射供冷系统使用。重点探讨了项目采用的防冻技术措施,提出了新风预热盘管电动调节阀最小开度的确定方法。
This paper presents the design of the cold and heat sources,heating and air conditioning water systems,air conditioning air systems and anti-freezing measures,etc.for the gymnasium.Combined with the gymnasium's function and the local dry-heat climate features,using indirect evaporative chillers provides high-temperature chilled water for floor radiation cooling system and pre-cooling section of air conditioning units of competition hall seat-air-supply system.This paper analyses the measures of anti-freezing in depth and proposes a method to confirm the minimum opening of electric regulating valves in an outdoor air pre-heating system.
作者
胡磊
董剑
王疆
陈焰华
卜萃文
Hu Lei;Dong Jian;Wang Jiang;Chen Yanhua;Bu Cuiwen(CITIC General Institute of Architectural Design and Research Co.,Ltd.,Wuhan;WISDRI Engineering and Research Incorporation Limited,Wuhan)
出处
《暖通空调》
2023年第3期84-88,66,共6页
Heating Ventilating & Air Conditioning
基金
国家重点研发计划政府间国际科技创新合作重点专项“应用于低碳区域能源系统的大规模水体储热模型及关键技术研究”(编号:2021YFE0113500)。
关键词
体育馆
冷热源
间接蒸发冷水机组
气流组织
防冻技术措施
电动调节阀
gymnasium
cold and heat source
indirect evaporative chiller
air distribution
anti-freezing measure
electric regulating valve