摘要 目的探討在線尿素清除率監測(Online Clearance Monitoring,OCM)在血液透析中的應用價值,評估監測血液透析Kt/V的可行性及準確性。方法利用德國B.Braun公司Dialog透析機OCM檢測血液透析患者的Kt/V值(online Kt/V);同時抽血檢測血液透析患者前後尿素氮濃度,根據Daugirdas公式計算Kt/V值(eKt/V)作爲對照,比較兩種方法的相關性,以及不同體重、超濾量及透析時間對Kt/V值的影響。結果本組293例維持性血液透析患者利用OCM檢測的online Kt/V值(1.82±1.27)高於常規抽血方法所得的eKt/V值(1.69±0.37),相關性分析顯示:兩者存在顯著的直線相關性(r=0.765,p<0.001)。不同體重≧60Kg及<60Kg的兩組患者中,體重大的一組,Kt/V數值較大:online Kt/V 1.93±1.32 VS 1.59±1.14;eKt/V 1.79±0.36 VS 1.47±0.26,(p<0.001)。同樣,本組資料中,不同超濾量≧3Kg及<3Kg的兩組資料中,超濾量大的一組Kt/V數值較大:online Kt/V1.85±1.30 VS 1.74±1.12;eKt/V 1.73±0.35 VS 1.61±0.30.(p<0.001)。在本研究中,透析時間長短對Kt/V值無顯著差別。結論對維持性血液透析患者OCM和常規方法所得的Kt/V值相關性較好,而且這種方法操作簡便,能保證患者透析的充分性,OCM檢測值稍高於Kt/V,臨床上應注意兩者的差別。 Objective To investigate the feasibility and accuracy of online clearance mornitoring(OCM)in assessing Kt/V value of hemodialysis adequacy by a auto-control study during hemodialysis.Methods Kt/V values of 293 patients with maintenance hemodialysis were assessed by OCM appliance on Dialog machine.Meanwhile,blood urea nitrogen(BUN)of pre-and post-dialysis were examined,and caculated the Kt/V value according to the Daugirdas formula,then evaluated the correlation between Kt/V by OCM and by calculation.Kt/V by OCM and by calculation were also compared in different body weight,ultrafitration volume,and time respectively.Results The value of Kt/V by OCM(1.82±1.27)was higher than the value of Kt/V by calculation(1.69±0.37)and correlation between Kt/V by OCM and by calculation was satisfactory(r=0.765,p<0.001).The value of Kt/V of the group with more body weight and more ultrafitration volume were higher than the other group(online Kt/V 1.93±1.32 VS 1.59±1.14;eKt/V 1.79±0.36 VS 1.47±0.26,p<0.001);(online Kt/V 1.85±1.30 VS 1.74±1.12;eKt/V 1.73±0.35 VS 1.61±0.30,p<0.001).However,there was no significant difference in Kt/V between the two groups with different dialysis time.Conclusion Correlation between Kt/V by OCM and by calculation was satisfactory.The operation of OCM was convenient and can guarantee hemodialysis adequacy.Kt/V values by OCM are usually higher than those calculated by calculation from urea measurements.This difference has to be considered in application of the results to clinical practice.
作者 彭洪泉 蕭浤 蔡宗仰 歐陽梓華 禤偉振 容旭燕 彭莉 PENG Hong Quan;XIAO Hong;TSAI Tsung Yang;AO leng Chi Wa;HUN Wai Chan;IONG Iok In;PENG Li(Department of Internal Medicine,Kiang Wu Hospital,Macao,China)
出处 《镜湖医学》 2013年第1期18-21,共4页 MEDICAL JOURNAL OF KIANG WU
关键词 在線尿素清除率監測(OCM) 血液透析 尿素清除率Kt/V Kt/V Online clearance monitoring(OCM) Hemodialysis
  • 相关文献

参考文献1

二级参考文献9

共引文献6

同被引文献5

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部