微种植体支抗不同植入部位推上颌磨牙远移的稳定性及对软组织侧貌美学的影响 被引量:1

The Stability of Microimplant Anchorage with Different Implant-positions in Pushing Maxillary Molars Displacement and Its Effect on Soft Tissue Profile Aesthetics
下载PDF
导出
摘要 目的:探讨微种植体支抗(Microimplant anchorage,MIA)不同植入部位推上颌磨牙远移的稳定性及对软组织侧貌美学的影响。方法:选择2018年1月-2020年12月笔者医院收治的90例非拔牙不完全Ⅱ类磨牙关系患者,按照随机数字表法分为腭侧组和颊侧组,每组45例。腭侧组患者于上颌双侧第一磨牙与第二前磨牙之间腭侧处各植入1枚微种植钉,颊侧组患者于上颌双侧第一、二磨牙之间颊侧处各植入1枚微种植钉。植入6个月后,比较两组第一磨牙远移距离、种植钉松动率及软组织侧貌美学参数(面型角、鼻唇角、上唇突度及下唇突度)。结果:腭侧组第一磨牙远移距离[(3.54±0.76)mmvs(2.60±0.61)mm]明显高于颊侧组,腭侧组的种植钉松动率(15.56%vs23.33%)明显低于颊侧组,差异均有统计学意义(P<0.05)。植入6个月后,两组下唇突度无明显变化(P>0.05);两组的面型角、上唇突度较植入前明显降低(P<0.05),两组比较差异无统计学意义(P>0.05);两组鼻唇角较植入前明显增高,腭侧组[(86.57±2.84)°vs(81.72±2.06)°]明显高于颊侧组,差异均有统计学意义(P<0.05)。结论:MIA腭侧植入推上颌磨牙远移的疗效明显,种植钉稳定性强,软组织侧貌美学效果好,优于颊侧植入。 Objective To discuss the stability of microimplant anchorage(MIA) with different implant-positions pushing maxillary molars displacement and its effect on soft tissue profile aesthetics. Methods A total of 90 non-extraction patients with incomplete Ⅱ Class molar relationship who were selected in our hospital from January 2018 to December 2020. The patients were divided into palatal side group and buccal side group according to random number table method, with 45 cases in each group. In the palatal side group, one microimplant screw was implanted in the palatal side between the first molars and the second premolars on bilateral maxillary. In the buccal side group, one microimplant screw was implanted in the buccal side between the first and second molars on bilateral maxillary. 6 months after implantation, the distance of the first molars, the loosening rate of implant screws and soft tissue profile aesthetic parameters(facial angle, nasolabial angle, upper lip protrudency and lower lip protrudency) were compared between two groups. Results The distance of the first molars[(3.54±0.76)mm vs(2.60±0.61)mm] in palatal side group was significantly higher than that in buccal side group(P<0.05). The loosening rate of implant screws(15.56% vs 23.33%) in palatal side group was significantly lower than that in buccal side group(P<0.05).6 months after implantation, there was no obvious change on lower lip protrusion in two groups(P>0.05). The facial angle and upper lip protrusion in two groups were significantly lower than those before implantation(P<0.05), and there was no significant difference between two groups(P>0.05). The nasolabial angle in two groups were significantly higer than that before implantation(P <0.05), the nasolabial angle[(86.57±2.84)°vs(81.72±2.06)°] in palatal side group was significantly higher than that in buccal side group(P<0.05). Conclusion MIA implantation in palatal side had obvious efficacy pushing maxillary molars displacement, with strong stability of implant screws and good aesthetic effect of soft tissue profile, which was superior to implantation in buccal side.
作者 谢琦 陈宇 史克佳 XIE Qi;CHEN Yu;SHI Kejia(Department of Stomatology,Langfang People's Hospital,Langfang 065000,Hebei,China)
出处 《中国美容医学》 CAS 2023年第2期127-130,共4页 Chinese Journal of Aesthetic Medicine
基金 2019年廊坊市科学技术研究与发展计划项目(名称:颧牙槽嵴种植支抗钉在无托槽隐形矫治技术中对Ⅱ类错牙合的临床研究,编号:2019013136)。
关键词 磨牙远移 上颌 微种植体支抗 腭侧 颊侧 稳定性 软组织 侧貌美学 molars displacement maxillary microimplant anchorage palatal side buccal side stability soft tissue profile aesthetics
  • 相关文献

参考文献14

二级参考文献97

共引文献67

同被引文献5

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部