期刊文献+

Analysis of electromagnetic characteristics of typical faults in permanent magnet wind generators

下载PDF
导出
摘要 Due to the harsh actual operating environment of the permanent magnet wind turbine,it is easy to break down and difficult to monitor.Therefore,the electromagnetic characteristics identification of major fault types of large-scale permanent magnet wind turbines is studied in this paper.The typical faults of rotor eccentricity,stator winding short circuit and permanent magnet demagnetization of permanent magnet wind turbines are analyzed theoretically.The wavelet analysis algorithm is used to decompose and reconstruct the abnormal electromagnetic signal waveform band,and the characteristic frequency of the electromagnetic signal is obtained when the fault occurs.In order to verify the effectiveness of the proposed method,a 3.680MW permanent magnet wind turbine was taken as the research object.Its physical simulation model was established,and an external circuit was built to carry out field co-simulation.The results show that the motor fault type can be determined by detecting the change rule of fault characteristic frequency in the spectrum diagram,and the electromagnetic characteristic analysis can be applied to the early monitoring of the permanent magnet wind turbine fault.
出处 《Global Energy Interconnection》 EI CAS CSCD 2023年第1期103-114,共12页 全球能源互联网(英文版)
基金 supported by the National Natural Science Foundation of China(U22A20215 and 51537007) the Natural Science Foundation of LiaoNing Province(2021-YQ-09).