摘要 本文提出了一种利用透射偏折术测量球面透镜结构参数的方法。该方法以本文推导的附加姿态参量的球面表达式构建透镜表面模型,同时结合系统标定数据在计算机中建立理想的光线追迹模型,最后利用非线性最优化算法计算得到透镜结构参数。在实验过程中,透镜出射光线的偏折量是两表面的累加和,难以确定单面的影响,因此采用双相机从不同位置观测待测透镜。文中详细介绍了测量原理以及算法,数值模拟结果验证了本方法的正确性。最后将双凸透镜结构参数的测量结果与标称值进行对比,对比结果进一步证明了所提方法的可行性。本方法具有测量参数齐全、无需精细装调过程、装置简单等优点,为透镜全参数同时测量提供了实现途径。 Objective Spherical lens plays an important role in the optical system,and spherical lens cannot be manufactured w ithout optical testing.The existing apparatus for measuring the structural parameters of spherical lens include:noncontact spherometer,coordinate measurement machine,and Abbey refractometers.However,these low-efficiency measuring apparatus can only measure one specific parameter at a time.Although the laser differential confocal interferometer can realize high-precision measurement for the full parameters of a lens,it is very expensive,and the complicated measurement optical path makes the installation and adjustment time-consuming.Phase measuring deflectometry(PMD)requires a simple device,is economical,and has a high dynamic range,which makes it popular.However,there is ambiguity among the structural parameters,refractive index,and thickness in the PMD measurement process.In this study,a method for measuring the structural parameters of a single lens by transmission deflectometry is proposed.This method can be used to measure the structural and postural parameters of lenses simultaneously.The measurement system is simple and does not require accurate alignment.We believe that the proposed method provides a novel way for the full-parameter measurement of spherical lenses.Moreover,it is also feasible for aspheric lenses.Methods Based on the principle of PMD,a structural parameter measuring method of a single lens by transmission d eflectometry was proposed.First,the single lens model was built in the coordinate system in the form of a polynomial,which was derived in detail in this study.Then,the models of the measurement system and lens were established in the software based on the calibration data from the experiment.From the reverse Hartman test perspective,rays were considered to emit from the pinhole of the camera and intersect the screen after being refracted by the lens.The difference between the intersection coordinates measured in the experiment and that traced in the software was used to construct the objective function.Furthermore,as the deflection magnitude of the emitted light was caused by the front and back surfaces of the lens being tested,it was difficult to obtain the correct results with only one camera.Therefore,a dual-camera device was employed to address this issue.Finally,by optimizing the structural and postural parameters of the lens in the model using the least squares algorithm,the real value could be obtained.Results and Discussions In this study,a double-convex lens was simulated and experimentally tested.In the numerical s imulation,the parameters of the lens were preset(Table 1),and the method proposed in this study was used for measurement.The simulation results show that the fitted values are basically the same as the preset values,and the relative errors are smaller than 4×10-4%.The effect of the calibration errors is shown in the simulation,and the results(Table 2)show that the relative errors are smaller than 0.3%and 2%for the structural and postural parameters,r espectively.In the experiment,the results(Table 3)show that the relative error of the lens structural parameter is smaller than 1%.As the lens postural parameters in the global coordinates are difficult to calibrate accurately,we verify t he sensitivity of the proposed method by measuring the variation of the lens postural parameters.The results(Fig.8)show that the proposed method has good measurement accuracy for pose parameters.Conclusions In this study,the structural parameter measuring method of a single lens by transmission deflectometry is pro posed.The numerical simulation results verify the feasibility of this method.The measurement accuracy of the proposed method is evaluated by measuring a double-convex lens in the experiment.The proposed method can measure multiple parameters simultaneously without requiring accurate adjustment.Moreover,the measurement cost is considerably lower compared with other existing methods.This new method facilitates full-parameter measurement for a single lens.Moreover,as the proposed method uses mathematical polynomials to construct the lens model and completes the lens parameter measurement by optimizing the polynomial coefficients,it is theoretically feasible for measuring other surfaces with higher degrees of freedom,such as aspheric surfaces.
作者 肖翔天 李大海 余林治 张新伟 阮一郎 Xiao Xiangtian;Li Dahai;Yu Linzhi;Zhang Xinwei;Ruan Yilang(College of Electronics and Information Engineering,Sichuan University,Chengdu 610065,Sichuan,China)
出处 《中国激光》 EI CAS CSCD 北大核心 2022年第23期64-71,共8页 Chinese Journal of Lasers
基金 国家自然科学基金(U20A20215,61875142) 四川大学基金(2020SCUNG205)。
关键词 测量 相位测量偏折术 双相机 光线追迹模型 透镜结构参数测量 measurement phase measuring deflectometry dual-camera ray-tracing model structural parameters measurement of lens
  • 相关文献

参考文献4

二级参考文献58

共引文献47

同被引文献32

引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部