期刊文献+

制酸系统净化工序电除雾器维修与改造实践

Maintenance and reformation practice of electric defogger in acid purification process
下载PDF
导出
摘要 针对制酸净化工序2台聚氯乙烯塑料、2台铅电除雾器在运行中出现的问题,及时进行了维修、更新和改造,最终都改为导电玻璃钢电除雾器。改造后4台电除雾器运行稳定,净化出口硫酸雾(ρ)在5 mg/m3以下。改造实践表明,导电玻璃钢电除雾器适合在行业内推广使用。 In view of the problems occurred in the operation of 2 sets of PVC plastic and 2 sets of lead electric mist eliminators in the acid making and purification process, they were repaired, updated and transformed in time, and finally changed to conductive FRP electric mist eliminators. After the transformation, four electric demisters operate stably, and the acid mist(ρ) at the purification outlet is below 5 mg/m3. The transformation practice shows that the conductive FRP electric mist eliminator is suitable for promotion and use in the industry.
作者 刘建萍 陈洪春 张均杰 LIU Jianping;CHEN Hongchun;ZHANG Junjie(Yantai Guorun Copper Industry Co.,Ltd.,Yantai,Shandong,264002,China)
出处 《硫酸工业》 CAS 2022年第11期19-23,33,共6页 Sulphuric Acid Industry
关键词 硫酸生产 净化工序 电除雾器 维修与改造 导电玻璃钢 sulphuric acid production purification process electric demister maintenance and transformation conductive FRP