10000t/d水泥线的NO_(x)超低排放应用实践 被引量:1

Ultra-low emissions of NO_(x) at 10 000 t/d cement plant
下载PDF
导出
摘要 通过优化设计自脱硝,抬高三次风风管,下移煤粉燃烧器,多层多点布置燃烧器,增大自脱硝还原区,提高自脱硝效率,实现NO_(x)本底排放低于350 mg/m^(3)。结合SNCR精准脱硝技术,多层多点布置喷枪,精确计量每组喷枪的氨水流量和压缩空气量,动态调节喷枪的雾化效果,控制烟囱NO_(x)排放(标况下)低于50 mg/m^(3),吨熟料氨水用量仅有2.0~2.2 kg/t。 By optimizing the design of self-denitration,raising the tertiary air duct,moving down the pulverized coal burner,setting the burners at different layers and positions,increasing the reduction zone of self-denitrification,improving the efficiency of self-denitrification,the original concentration of NO_(x) is less than 350 mg/m^(3).Combined with SNCR denitration technology,the spray gun are set at different layers and positions,the ammonia flow and compressed air volume of each spray gun are accurately measured,and the atomization effect of the spray gun is dynamically adjusted.The emission of NO_(x) is controlled below 50 mg/m^(3)at chimney(Under standard conditions),and the consumption of ammonia per ton of clinker is only 2.0~2.2 kg/t.
作者 朱永长 朱刚 何剑波 严晨 吴加刚 卢仁红 周丽云 Zhu Yongchang;Zhu Gang;He Jianbo;Yan Chen;Wu jiagang;Lu Renhong;Zhou Liyun(Sinoma International Engi-neering Co.,Ltd.,Nanjing,211100 China)
出处 《水泥工程》 CAS 2023年第1期43-44,75,共3页 Cement Engineering
关键词 自脱硝 SNCR 超低排放 self-denitration SNCR ultra-low emissions