摘要 目的评估一种肝脏金标植入新方法在兔肝脏内固定及取出的可行性,以期用于射波刀金标追踪治疗。方法分为活体实验和离体实验。活体实验对10只家兔麻醉后,经皮肝穿刺植入3颗金标,10 d后植入设有外置套管和固定细线的第4颗金标,以射波刀分别对参照组(第1颗和第2颗)和套管组(第1颗和第4颗)配准后追踪,施照结束后,评估金标植入成功率、配准精度及取出的安全性。离体实验在离体的肝脏进行金标拉力测试,测量弹簧圈金标和无弹簧圈金标取出时所受阻力。结果实验过程中金标没有出现远处转移的情况,植入与回收成功率均为100%。操作过程家兔未发生明显相关并发症和术后并发症。所有金标均成功追踪,套管组的配准平移偏差在头脚方向和前后方向高于参照组(Z=-11.77、-4.57,P<0.05),而左右方向低于参照组(Z=-2.52,P<0.05)。金标拉力测试结果显示弹簧圈金标拉力为(2.23±0.85)N,无弹簧圈金标拉力为(0.81±0.13)N,差异有统计学意义(Z=-2.31,P<0.05)。结论螺旋线圈结构金标在穿刺针道内的固定效果好,细线限制了金标肝外远处移位,套管为金标回收建立通道,整体操作简单易行。 Objective To evaluate the feasibility of a novel liver fiducial marker implantation method for internal fixation and removal of rabbit livers,in order to use in Cyberknife tracking therapy.Methods Experiments were conducted in vivo and in vitro.In the in vivo experiment,three fiducial markers were implanted percutaneously in each liver of ten rabbits under anesthesia,and the fourth fiducial marker with an external catheter and fixed thin wire was implanted ten days later.After the reference group(the first and the second maker),and the casing group(the first and the fourth marker)were respectively registered and tracked with the Cyberknife,the implantation success rate,registration accuracy,and removal safety of fiducial markers were assessed.The tensile test was performed using liver in vitro by measuring the resistance required to dislodge the spring coil fiducial markers and the fiducial markers without spring coil from liver.Results The intrahepatic catheter implantation and removal of fiducial marker in rabbit liver had a success rate of 100%and no distant migration.The operation-related and postoperative complications were not occurred.All fiducial markers were successfully traced.Compared to the reference group,the casing group had slightly higher translational errors in supero-inferior and antero-posterior directions(Z=-11.77,-4.57,P<0.05),and lower translational errors in left-right direction(Z=-2.52,P<0.05).The dislodgement forces for spring coil fiducial markers was(2.23±0.85)N,significantly different with(0.81±0.13)N for fiducial markers without spring coil(Z=-2.31,P<0.05).Conclusions The spiral coil structure provides superior fixation in the punctured needle channel,the thin line limits the distant displacement of the fiducial marker outside the liver,and the catheter establishes a channel for the removal.The general operation is simple and easy.
作者 邓显智 陈静 林漳华 李诺兮 董芳芬 何善廷 张建平 徐本华 马家骏 李小波 Deng Xianzhi;Chen Jing;Lin Zhanghua;Li Nuoxi;Dong Fangfen;He Shanting;Zhang Jianping;Xu Benhua;Ma Jiajun;Li Xiaobo(School of Medical Imaging,Fujian Medical University,Fujian Medical University Cancer Center,Fujian Key Laboratory of Intelligence Imaging and Precision Radiotherapy for Tumors,Clinical Research Center for Radiology and Radiotherapy of Fujian Province(Digestive,Hematological and Breast Malignancies),Fuzhou 350001,China;Department of Biomedical Engineering,School of Medicine,Tsinghua University,Beijing 100084,China;Department of Radiation Oncology,Fujian Medical University Union Hospital,Fuzhou 350001,China;Department of Engineering Physics,Tsinghua University,Beijing 100084,China)
出处 《中华放射医学与防护杂志》 CAS CSCD 北大核心 2023年第2期81-86,共6页 Chinese Journal of Radiological Medicine and Protection
基金 福建省医学创新课题(2020CXA026) 福建省卫生健康青年科研课题(2002QNA027)。
关键词 可回收金标 经皮经肝穿刺 射波刀 家兔 Recoverable fiducial marker Percutaneous transhepatic implantation Cyberknife Rabbit
  • 相关文献

参考文献2

二级参考文献5

共引文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部