期刊文献+

基于图像质量评价的手术机器人系统磁共振兼容性分析方法

Magnetic Resonance Compatibility Analysis Method of Surgical Robotic System Based on Image Quality Evaluation
下载PDF
导出
摘要 为保证手术安全及操作精度,基于磁共振图像导航的手术机器人系统需具备磁共振设备兼容性.针对这一问题,本文提出了基于磁共振图像质量评价的手术机器人系统磁共振设备兼容性分析方法,扩展了图像数据集,并结合图像信噪比、图像变化因数、磁共振图像畸变量等评价参数,逐一分析机器人系统组件通电、机器人系统运动对磁共振图像质量产生的影响,建立图像质量评价依据.实验结果表明,该质量评价方法可充分分析手术机器人及其系统组件的磁共振兼容性,且可为医疗手术机器人系统组件的磁共振兼容性分析提供测试方法与理论依据. To ensure the safety and precision of surgery,the robotic system applied in magnetic resonance(MR)image-guided robot-assisted surgery should be MR-compatible.In terms of this issue,a MR compatibility analysis method for surgical robotic system based on image quality evaluation is proposed in this paper,and the image sets are extended.The image quality evaluation model is constructed by combining evaluation parameters such as signal-to-noise ratio of MR images,image change factor and MR image distortion.The model can analyze the effect of the robot component and robot motion on image quality,forming a basis for image quality evaluation.The experimental results show that the image quality evaluation method can fully analyze the MR compatibility of the robotic system component,and provide an evaluative method and theoretical basis for the MR compatibility analysis of other kinds of medical robotic systems.
作者 李盼 房德磊 张峻霞 马得贝 LI Pan;FANG Delei;ZHANG Junxia;MA Debei(College of Mechanical Engineering,Tianjin University of Science&Technology,Tianjin 300222,China;Tianjin Key Laboratory of Integrated Design and On-line Monitoring for Light Industry&Food Machinery and Equipment,Tianjin 300222,China;Department of Radiology,Tianjin Medical University Cancer Institute&Hospital,Tianjin 300060,China)
出处 《波谱学杂志》 CAS 北大核心 2023年第1期79-91,共13页 Chinese Journal of Magnetic Resonance
基金 国家自然科学基金资助项目(52005369) 天津市应用基础研究项目(22JCQNJC00450) 天津市教委科研计划项目(2019KJ226) 天津市重点实验室开放基金项目(2020LIMFE03)。
关键词 磁共振成像 磁共振兼容性 图像质量评价 信噪比 手术机器人 magnetic resonance imaging(MRI) magnetic resonance compatibility image quality evaluation signal-to-noise ratio surgical robot
  • 相关文献

参考文献8

二级参考文献48

  • 1Oh C H, Ryu Y C, Hyun J H, et al. Dynamic range expansion of receiver by using optimized gain adjustment for high-field MRI[J]. Concept Magn Reson A, 2010, 36A: 243 -254.
  • 2Elliott M A, Insko E K, Greenman R L, et al. Improved resolution and signal-to-noise ratio in MRI via enhanced signal digitization[J]. J Magn Reson, 1997, 130: 300-304.
  • 3Mandsley A A. Dynamic range improvement in NMR imaging using phase scrambling[J]. J Magn Reson, 1987, 76: 287- 305.
  • 4Wedeen V J, Chao Y, Ackerman J L, et al. Dynamic range compression in MRI by means of nonlinear gradient pulse[J]. Magn Reson Med, 1988, 6: 287-295.
  • 5Oh C H, Hilal S K, Wu E X, et al. Phase-scrambled RF excitation for 3D volume-selective multislice NMR imaging[J]. Magn Reson Meal, 1992, 28: 290-299.
  • 6Johnson G, Wu E X, Hilal S K, et al. Optimized phase scrambling for RF phase encoding[J]. J Magn Resort B, 1994, 103: 59-63.
  • 7Maudsley AA. Sensitivity in fourier imaging[J]. J Magn Reson, 1986, 68:363 -366.
  • 8Behin R, Bishop J, Henkelman R M, et al. Dynamic range requirements for MRI[J]. Concept Magn Reson B, 2005, 26B: 28-35.
  • 9Otake Y, Kose K, Haishi T, et al. A solution to the dynamic range problem in MRI using a parallel imaging acquisition[J]. Concept Magn Reson B, 2006, 29B: 161-167.
  • 10Takeda K, Takegoshi K. Noise reduction by dynamic signal preemphasis[J]. J Magn Reson, 2011, 208: 305-308.

共引文献26

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部