《建筑给水排水设计标准》(GB50015-2019)已于2020年3月1日起实施。该规范结合最新科研成果及工程实践对2009年版规范中部分条文进行了修订。本文采用2019年版、2009年版规范给水设计秒流量计算公式对长沙两类宿舍楼进行了计算与比较,分析了计算结果产生差别的原因,探讨了2019年版规范的适用性,并提出了相应的建议。
Standard for design of building water supply and drainage(GB 50015-2019)has been implemented since March 1,2020.According to the latest scientific research results and engineering practice,part of the provisions of the 2009 edition of the standard have been revised.In this paper,two types of dormitories in Changsha are calculated and compared by using the calculation formula of the design peak flow in water supply of the 2019 edition and the 2009 edition of the standard,the reasons for the difference in the calculation results are analyzed,the applicability of the 2019 edition of the code is discussed,and the corresponding suggestions are put forward.