摘要
针对后处理厂非接触式测量,对吹气测量系统进行优化设计,提出了一种简单有效的可防止管路结晶的吹气法测量装置,并结合工程实际运行工况,对DCS系统进行协同调整,形成一套完整的运行方案。
In this paper,optimize the design of blowing measurement system for non-contact measurement of nuclear chemical plant,and propose a simple and effective blowing method measurement device that can prevent pipeline crystallization which combined with the actual operating conditions of the project.Finally,it would make synergistic adjustments to the DCS system to form a complete operating scheme.
作者
宝音
朱凌佳
孟祥达
王志勇
Bao Yin;Zhu Lingjia;Meng Xiangda;Wang Zhiyong(China Nuclear Power Engineering Co.,Ltd.,Beijing,100840,China)
出处
《仪器仪表用户》
2023年第4期53-55,84,共4页
Instrumentation
关键词
吹气装置
增湿压空
结晶
blowing device
humidification
crystallization