期刊文献+

高精度三通换向阀设计及试验研究 被引量:1

Design and Experimental Research of High-Precision Three-Way Directional Valve
下载PDF
导出
摘要 液体流量标准装置和高精度称量系统的主要部件为换向器。换向器的性能是影响液体流量装置不确定度的主要因素。传统换向器因其结构上的特点,很难再提高其性能。设计了一种创新结构的高精度三通换向阀。介绍了高精度三通换向阀的运行原理和内部结构。对高精度三通换向阀与普通换向器在水流量标准装置上进行了标定和对比试验。试验结果表明,相较于普通换向器,高精度三通换向阀拥有尺寸紧凑、切换速度快、重复准确性和稳定性高等优点。使用高精度三通换向阀作为液体流量标准装置的换向器,能极大地提高液体流量装置的检测能力和效率。 The main component of liquid flow standard devices and high precision weighing systems is the commutator.The performance of commutator is the main factor that affects the uncertainty of liquid flow device.The conventional commutator is difficult to improve its performance further due to its structural characteristics.A high-precision three-way directional valve with an innovative structure is designed.The operation principle and internal structure of the high-precision three-way directional valve are introduced.Calibration and comparison tests are conducted between the high-precision three-way directional valve and the common reverser on the water flow standard device.The test results show that compared with the common commutator,the high-precision three-way directional valve has the advantages of compact size,fast switching speed,high repeatable accuracy and stability.Using the high-precision three-way directional valve as the commutator of the liquid flow standard device can greatly improve the detection capability and efficiency of the liquid flow device.
作者 陈丽萍 CHEN Liping(Shanghai SIPAI Automation Technology Co.,Ltd.,Shanghai after addition 200233,China)
出处 《自动化仪表》 CAS 2023年第3期107-110,共4页 Process Automation Instrumentation
关键词 流量装置 高精度三通换向阀 换向器 结构设计 不确定度 Flow device High-precision three-way directional valve Commutator Structure design Uncertainty
  • 相关文献

参考文献5

二级参考文献25

  • 1陈程,孙自强.德士古水煤浆气化炉炉温监控系统的开发[J].自动化仪表,2005,26(10):44-46. 被引量:8
  • 2黄中原,刘健,秦春节.基于组态王的空压机远程监控系统研究[J].压缩机技术,2006(1):18-19. 被引量:7
  • 3史振东,李旭,王东伟.两种换向器在液体流量标准装置中的应用[J].计量技术,2006(12):65-66. 被引量:16
  • 4苏彦勋,梁国伟,盛健.流量计量与测试[M].北京:中国计量出版社,2007.
  • 5JJG164--2000,液体流量装置检定规程[S].
  • 6Paik J S. Draft B Report on CCM. FF- K1 for Water Flow [R]. 2006,11-13.
  • 7T. Shimada, S. Oda, Y.Terao, et al.Development of a New Diverter System for Liquid Flow Calibration Facilities, Flow Meas. Instrum.,2003,14:89-96.
  • 8R. Doihara, T. Shimada, Y.Terao, et al. Development of Weighing Tank System Employing Rotating Double Wing Diverter, Flow Meas. Instrum.,2006,17:141-152.
  • 9W. Poeschel, R. Engel, D. Dopheide, et al. A Unique Fluid Diverter Design for Water Flow Calibration Facilities, Proceedings of the 10th International Conference on Flow Measurement(FLOMEKO 2000),Salvador, June 5-8,2000.
  • 10Engel, Rainer. Modeling the Uncertainty in Liquid Flowmeter Cali- bration and Application-Requirement and Their Technical Realiza- tion for PTB's National Water Flow Standard[ C ]//SENSOR Con- ference 2007 Proceedings Ⅱ.