期刊文献+

计及变流器影响的直驱式永磁同步发电机二阶自抗扰控制 被引量:2

SECOND-ORDER ACTIVE DISTURBANCE REJECTION CONTROL OF DIRECT-DRIVEN PERMANENT MAGNET SYNCHRONOUS GENERATORS CONSIDERING INFLUENCE OF CONVERTER
下载PDF
导出
摘要 研究基于新型自抗扰技术的直驱式永磁同步发电机电气控制系统。考虑变流器对控制系统输出电压的影响,建立发电机组的数学模型,以此为基础设计二阶自抗扰控制器,对设计的扩张状态观测器和控制器的收敛性进行分析并给出控制参数配置方法。通过仿真对所提控制系统的可行性及控制性能进行定量分析,结果表明,该控制系统能够快速稳定的控制发电机组的运行过程,且相比传统的矢量控制及一阶自抗扰控制具有更好的动态性能及鲁棒性能。 An electric control system of direct-drive permanent magnet synchronous generator based on new active disturbance rejection technology is studied. Considering the influence of the converter on the output voltage of the control system,a mathematical model of the generator set is established,and based on this,a second-order active disturbance rejection controller(ADRC)is designed. The proposed extended state observer and the convergence of the controller are analyzed,and the control parameter configuration method is given. The feasibility and control performance of the proposed control system are quantitatively analyzed by simulation. The results show that the proposed control system can control the operation process of the generator set quickly and stably,and has better dynamic performance and robust performance than the traditional vector control and first-order ADRC.
作者 祝可可 阮琳 Zhu Keke;Ruan Lin(Institute of Electrical Engineering Chinese Academy of Sciences,Beijing 100190,China;University of Chinese Academy of Sciences,Beijing 100049,China)
出处 《太阳能学报》 EI CAS CSCD 北大核心 2023年第2期87-92,共6页 Acta Energiae Solaris Sinica
关键词 风力发电 控制策略 鲁棒性 变流器 二阶自抗扰控制器 wind power control strategy robustness converter second-order active disturbance rejection controller
  • 相关文献

参考文献12

二级参考文献124

共引文献332

同被引文献18

引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部