摘要
结合国内某天然气分布式能源站的集控室空调系统,对比分析了三种典型的一次回风全空气系统和一种温湿度独立控制的一次回风全空气系统。结果表明,电厂控制室空调过程可按等湿过程考虑,露点送风的送风温差过大,不适用于集控室空调系统,改进的温湿度独立控制全空气系统具有明显的节能降耗效果,可为设计人员提供借鉴参考。
Combined an air-conditioning system of centralized control room in a gas-fired distributed energy station,three kinds of typical primary return air air-conditioning system and an temperature and humidity independent control air conditioning system have been studied.Found that the air conditioning process of the centralized control room can be considered as the isohumidity process.Temperature difference of supplying air in dew point is too large,so it is not suitable for the air conditioning system for centralized control room.The temperature and humidity independent control air conditioning system has obvious energy saving effect and it can be referenced by the design personnel.
作者
倪明龙
盛帮明
Ni Minglong;Sheng Bangming
出处
《洁净与空调技术》
2023年第1期55-58,共4页
Contamination Control & Air-Conditioning Technology
基金
H级燃机综合创新优化技术研究(32-JK-2021-019)。
关键词
分布式能源站
一次回风
温湿度独立控制
系统对比
节能降耗
Gas-fired distributed energy station
Primary return air
Temperature and humidity independent control
System comparison
energy saving