常减压装置3级电脱盐投用效果分析

Analysis on the effect of 3-stage electric desalting in atmospheric and vacuum plant
下载PDF
导出
摘要 针对常减压装置2019年前因原油中腐蚀介质含量高,反复出现腐蚀泄露和设备结垢此问题,结合腐蚀机理和装置实际情况,利用检修时机对装置进行优化,增加1个电脱盐罐,投用3级电脱盐流程后,原油中的无机盐和水得以进一步脱除,脱后原油盐含量和水含量明显降低,装置腐蚀在线监测数据显示,腐蚀速率得到极大改善。 Due to the high content of corrosive media in crude oil, corrosion leakage and equipment scaling occurred repeatedly in atmospheric and vacuumplant before 2019. Combined with the corrosion mechanism and the plant actual situation, it optimizedthe plantduring the overhaul period, added an electrodesalination tank, and put the three-stage electrodesalination process into use to make the inorganic salts and water in crude oil further removed. After that, the salt and watercontent was decreased obviously, and the corrosion rate was greatly improved according to the on-line corrosion monitoring data.
作者 张晓琳 李博文 张公鑫 侯庆东 韩纪宇 Zhang Xiaolin;Li Bowen;Zhang Gongxin;Hou Qingdong;Han Jiyu(PetroChina Liaoyang Petrochemical Company,Liaoyang 111003,China;China National Oil and Gas Exploration and Development Company Ltd.,Beijing 100034,China)
出处 《炼油与化工》 CAS 2023年第1期46-48,共3页 Refining And Chemical Industry
基金 辽阳石化公司《炼油厂常减压装置增设电脱盐及工艺防腐设施改造》项目。
关键词 常减压 电脱盐 腐蚀 atmospheric and vacuum plant electrodesalination corrosion