期刊文献+

铬天青S差示光度法测定铍精矿、绿柱石中氧化铍量 被引量:1

Determination of Beryllium Oxide in Beryllium Concentrate and Beryl by Chromazurol S Differential Spectrophotometry
下载PDF
导出
摘要 铬天青S光度法能够准确测定氧化铍,经引入1,2—环己二胺四乙酸(CYDTA)等高浓度、高络合剂,使方法有了优良的抗干扰能力,操作较为简便。在此基础上,对这一分析方法开展了进一步研究,从样品加工开始,严格控制条件,能够准确测定5%~14%氧化铍,可以代替重量法并及时提出可靠的分析报告,该法用于实验室检测样品分析,已经取得较好结果。 Chromazurol S spectrophotometry can accurately determine beryllium oxide.The introduction of high concentration and high complexing agents such as 1,2-cyclohexanediamine tetraacetic acid(CYDTA)has provided the method with excellent anti-interference ability and relatively simple operation.On this basis,further research has been carried out on this analytical method.Starting from sample processing,strict control of conditions can accurately determine 5%to 14%beryllium oxide,which can replace the gravimetric method and provide reliable analytical reports in a timely manner.This method has been used for the analysis of laboratory test samples and has achieved good results.
作者 王应平 秦红艳 段玲敏 戈润滔 Wang Yingping;Qin Hongyan;Duan Lingmin;Ge Runtao(Geological Geophysical and Chemical Exploration Institute of Yunnan Non ferrous Geology Bureau(Testing Center of Yunnan Non ferrous Geology Bureau),Kunming,Yunnan 650216,China)
出处 《云南化工》 CAS 2023年第3期80-82,共3页 Yunnan Chemical Technology
关键词 铬天青S 差示光度法 氧化铍 Chromazurol S differential spectrophotometry beryllium oxide
  • 相关文献

参考文献3

二级参考文献1

  • 1斯皮钦B N.铍化学及工艺学[M].北京:中国工业出版社,1965..

共引文献28

同被引文献19

引证文献1

二级引证文献2

相关作者