摘要
抗压强度是蒸压加气混凝土砌块的常见检测指标之一,而含水率的结果对其有着较大的影响。本文采用三种不同调湿方案对蒸压加气混凝土砌块抗压强度检测结果进行了研究。结果表明,采用养护箱调湿法进行调湿,试件含水率均匀,标准差小,抗压强度检测结果适中。成果可为开展蒸压加气混凝土砌块的检验检测工作提供技术参考。
In this paper,three different humidification schemes are adopted to study the compressive strength test results of autoclaved aerated coagulation.The results show that when the autoclaved aerated concrete blocks are placed in a water curing box for humidity adjustment,the treated samples have uniform moisture content and accurate compressive strength.This provides a technical reference for testing autoclaved aerated concrete blocks.
作者
范永康
王强
殷又清
FAN Yong-kang;WANG-Qiang;YIN You-qing
出处
《砖瓦》
2023年第4期22-24,共3页
Brick-tile
关键词
蒸压加气混凝土
调湿
抗压强度
autoclaved aerated concrete
humidification control
compressive strength