期刊文献+

快速测量Xe稳定同位素丰度及其质量歧视校正 被引量:1

Rapid Measurement of Xe Stable Isotope Abundance and Mass Discrimination Correction
下载PDF
导出
摘要 为准确测量Xe同位素丰度,本研究针对Xe同位素电离后各离子在磁场中的运动特征设定了MAT253型质谱计法拉第杯的位置,并用其快速测量了天然Xe的9种同位素丰度。MAT253作为一种磁质谱计,为解决测量同位素丰度时的质量歧视效应问题,采用内标法,利用幂函数、指数和平衡校正规律对Xe同位素丰度的质量歧视进行校正。测量结果的相对标准偏差≤0.13%,而以131 Xe/132 Xe做为内标的幂校正方法,得到的Xe同位素丰度更接近于参考值。校正后各同位素与参考值的偏差均≤1.46%,且各同位素的标准不确定度均≤0.21%(k=2)。 In this study,the position of Faraday Cup of MAT253 mass spectrometer was set according to the motion characteristics of ions in magnetic field after Xe isotope ionization,and the abundance of nine Xe isotopes were measured,in order to accurately measure the Xe isotopic abundance.As a magnetic mass spectrometer,MAT253 has mass discrimination effect when measuring isotope abundance.To address this issue,the internal standard method was used to correct the mass discrimination of Xe isotope abundance values by using power function,exponential function and equilibrium correction law.The relative standard deviation of measurement results was less than or equal to 0.13%,and the Xe isotope abundances obtained by the power fuction correction with 131 Xe/132 Xe as internal standard were closer to the natural values.The corrected deviation of each isotope from the reference values were within 1.46%,and the standard uncertainty of each isotope was within 0.21%(k=2).
作者 曹金浩 杨凤诚 侯超 窦鑫 刘佳龙 CAO Jinhao;YANG Fengcheng;HOU Chao;DOU Xin;LIU Jialong(Research Institute of Physical and Chemical Engineering of Nuclear Industry,Tianjin 300180,China)
出处 《同位素》 CAS 2023年第2期168-175,I0003,共9页 Journal of Isotopes
关键词 MAT253质谱计 Xe同位素 质量歧视 幂校正 MAT253 mass spectrometer Xe isotope mass discrimination power correction
  • 相关文献

参考文献4

二级参考文献15

  • 1张小枝,刘大鸣,李金英,李安利,金小海.后处理厂释放气体中稳定惰性气体同位素在核保障监督中的应用研究[J].核化学与放射化学,2004,26(4):198-203. 被引量:6
  • 2VANCE D, THIRLWALL M. An assessment of mass discrimination in MC-ICPMS using Nd isotopes[J]. Chem Geol, 2002,185 : 227-240.
  • 3WOMBACHER F, REHKAMPER M. Investigation of the mass discrimination of multiple collector ICPMS using neodymium isotopes and the generalised power law[J]. J Anal At Spectrom, Z003, 18: 1 371-1 375.
  • 4BECKER H, DALPE C, WALKER R J. Highprecision Ru isotopic measurements by multi-collector ICP-MS[J]. Analyst, 2002, 127:775-780.
  • 5MARECHAL C N, TELOUK P, ALBAREDE F. Precise analysis of copper and zinc isotopic compositions by plasma-source mass spectrometry[J]. Chem Geol, 1999,156:251-273.
  • 6Martin JT Milton, Jian Wang. High Accuracy Method for Isotope Dilution Mass Spectrometry With Application to the Measurement of Carbon Dioxid[J]. Int J Mass Spectrom, 2002, (218):63-73.
  • 7Zhu Z R,Earth Planet Sci Lett,1993年,118卷,281页
  • 8Chen J H,Geol Soc Am Bull,1991年,103卷,1期,82页
  • 9Ku T L,Quarter Res,1990年,33卷,129页
  • 10夏明,铀系年代学方法及实验技术,1989年,105页

共引文献13

同被引文献5

引证文献1

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部