合理的供水设施规模以及提高管网内水的流动性是保障建筑室内饮用水水质的有效措施。结合两个工程案例,指出了较高的管道流速有利于控制供水管网管道容积,建议水池补水采用多级可调模式以应对给水系统低负荷运行状态,通过采用末端自动定时放水装置避免管网长时间滞水。
Reasonable scale of water supply facilities and improvement of water flow in the pipe network are effective measures to ensure the quality of drinking water in the buildings.Combined with two engineering cases,it is pointed out that higher pipeline flow rate is beneficial to control the scale of water supply network.It is suggested that the multi-stage adjustable mode should be adopted for the water supplement of the tank to cope with the low load operation state of the water supply system,and the Automatic end timing water discharge devices should be used to avoid the long-term water stagnation of the network.
作者
王学良
朱文倩
WANG Xueliang;ZHU Wenqian(East China Architectural Design&Research Institute,Shanghai 200002,China)
出处
《给水排水》
CSCD
北大核心
2023年第3期81-86,共6页
Water & Wastewater Engineering
关键词
水力停留时间
管道流速
末端自动放水
Hydraulic retention time
Pipe velocity
Automatic end water discharge