期刊文献+

基于火电站转型储能电站的超高温热泵及熔盐储换热系统工程应用设计 被引量:2

Engineering Application Design of Ultra-high Temperature Heat Pump and Molten Salt Heat Storage and Exchange System Based on the Rmal Power Station Transformation to Energy Storage Power Station
下载PDF
导出
摘要 基于300MW等级亚临界参数燃煤电站向储能电站转型的应用场景,搭建了超高温热泵及熔盐储换热系统,并系统性研究了循环压力区间和低温热源温度对超高温热泵制热COP的影响。本系统在550℃制热温度下获得了1.2623的制热效率,通过规划电站运行模式设计,最终实现可再生能源冗余发电的“电-热-电”系统循环转化效率可达到57.162%。 Based on the application scenario of 300MW subcritical parameter coal-fired power station transitioning to energy storage power station,the author built an ultra-high temperature heat pump and molten salt heat storage and exchange system,and systematically studied the effect of cycle pressure range and low temperature heat source temperature on the COP of ultra-high temperature heat pump heating.The system achieves a heating efficiency of 1.2623 at a heating temperature of 550℃.Through planning the operation mode design of the power station,the cycle conversion efficiency of the"electricity-heat-electricity"system of redundant power generation of renewable energy can reach 57.162%.
作者 赫广迅 宋业琛 HE Guang-xun;SONG Ye-chen(Harbin Turbine Company Limited,Harbin 150046,China;China United Heavy Duty Gas Turbine Technology Co.,Ltd.,Beijing 102209,China)
出处 《汽轮机技术》 北大核心 2023年第2期93-96,146,共5页 Turbine Technology
关键词 超高温热泵 熔盐储换热 储能电站 循环效率 ultra-high temperature heat pump molten salt heat storage andexchange energy storage power station cycle efficiency
  • 相关文献

参考文献8

二级参考文献66

  • 1占超群 代谦.《为出口而进口?中国进出口关系的实证分析》[J].发展经济学论坛,2010,.
  • 2热泵原理及其在国外使用情况.第四设计研究院情报室,1979:1-14.
  • 3Eisa M A R, Chaudhari S k, Paranjape D V %et al.% Classified references jar absorption heat pumps from 1975 to May 1985. Heat Recovery&CHP,1986,6(5).
  • 4H Iwano. Develipment of absorption type air conditioners for residential use. Preprints in 1995 international gas research conference, V IV:11-22.
  • 5Shelton S A. Residential space conditioning with solid sorption technology. Heat Recovery Systems & CHP, 1993,13(4),353-361.
  • 6Douss N, Meunier F E. Adsorptive heat pump: active carbon-methanol pair. LIMSICNRS BP 30,91406, Drsay(France)..
  • 7Raldow W M, Wentworth W E. Chemical heat pumps-a basic thermodynamic analysis, Solar Energy,1979,23:75.
  • 8R D Washington. Chem Eng News. Vol.58, 1980,No.42, 36-37.
  • 9P. Xu, Y. Chen and X. Ye, "Haze, Air Pollution, and Health in China, " The Lancet, vol.382, no. 9910, 2013, p.2067.
  • 10中国煤炭资源网,http://www.sxcoal.com/coal/3275622/articlenew.html.