期刊文献+

绝缘电阻表检定与测量结果的不确定度评定

Verification of Insulation Resistance Meter and Evaluation of Uncertainty of Measurement Results
下载PDF
导出
摘要 阐述ZC11D-10的10级绝缘电阻表的检定,结果可得其基本误差为3%,符合10.0级,检定合格。根据GUM法对测量结果进行不确定度评定,对各相关分量分析汇总,得到电阻为100MΩ时,U=1.3MΩ(k=2);开路电压为500V时,U=5.8V(k=2)。该结论可为日后的检定校准提供依据。 This paper describes the verification of the 10-level insulation resistance meter of ZC11D-10. The results show that the basic error is 3%, which is in line with the 10.0 level and is qualified. The uncertainty of the measurement results is evaluated according to the GUM method, and the relevant components are analyzed and summarized. When the resistance is 100M Ω, U=1.3M Ω(k=2);When the open-circuit voltage is 500V, U=5.8V(k=2). This conclusion can provide a basis for future verification and calibration.
作者 朱羽萌 徐鹏 冯跃娟 ZHU Yumeng;XU Peng;FENG Yuejuan(China North Engine Research Institute,Tianjin 300400,China;Tianjin Youzhiheng New Energy Technology Co.,Ltd.,Tianjin 300400,China)
出处 《集成电路应用》 2023年第1期321-323,共3页 Application of IC
关键词 绝缘电阻表 检定 不确定度评定 insulation resistance meter verification uncertainty evaluation