摘要
梳理各种干扰对仪器的影响,有助于更好地识别前兆异常,消除干扰可以提高数据观测质量。本文从观测系统、自然环境、人为干扰等方面对榆社红崖头观测站水位典型干扰进行归类分析,并给出相应的解决途径。分析结果表明,红崖头井水位受到的观测系统干扰主要为供电故障、电源电压不稳、泄流系统干扰;自然环境干扰主要为强对流天气;人为干扰主要包括探头位置改变、取水样等。
Sorting out the influence of various interferences on instruments is helpful to better identify precursor anomalies,and eliminating interference can improve the quality of data observation.This paper classifies and analyzes the typical interference factors of the water level at Hongyatou Observation Station in Yushe from the aspects of the observation system,natural environment and human interference and gives the corresponding solution.The results show that the observation system interferences mainly include the failure of power supply,unstable power voltage and blockage of flow discharge system.The natural environment interferences mainly include severe convective weather.The human interferences mainly include the change of probe position and water sampling.
作者
宫静芝
张亮娥
吕永青
王振江
GONG Jingzhi;ZHANG Liang’e;LÜYongqing;WANG Zhenjiang(Taiyuan Earthquake Monitoring CenterStation,Shanxi Earthquake Agency,Shanxi Province 030025,China;National Continental Rift Valley Dynamics Observatory of Taiyuan,Shanxi Province 030025,China)
出处
《地震地磁观测与研究》
2022年第6期101-106,共6页
Seismological and Geomagnetic Observation and Research
基金
山西省地震局科研项目(项目编号:SBK-1814)
山西太原大陆裂谷动力学国家野外科学观测研究站研究课题(项目编号:NORSTY20-10)。
关键词
水位
典型干扰
解决途径
影响因素
泄流系统
water level
typical interference
solution
influencing factors
flow discharge system