摘要
通过实验室与现场测试验证了不同行业工况下烟尘颗粒物对基于β射线法烟尘直读仪的数据影响分析,分析了实验室验证数据产生负偏差的原因及解决措施,综合实验室与现场验证数据得出β射线法的烟尘直读仪测量数据不仅准确度高,而且与重量法数据相关性高,说明了β射线法烟尘直读仪不受不同行业工况的烟尘颗粒物影响。
Through laboratory and field tests,the causes of the negative deviation of laboratory verification data are analyzed.The verification data shows that the measurement data of theβ-ray method is not only highly accurate,but also highly correlated with the data using the gravimetric method,indicating that theβ-ray method is not affected by soot particles under different industry conditions.
作者
李金莹
秦承华
田红兵
李德安
高捷
王婷
谢元壮
梅金
Li Jinying;Qin Chenghua;Tian Hongbing;Li De’an;Gao Jie;Wang Ting;Xie Yuanzhuang;Mei Jin(Qingdao Minghua Electronic Instrument Co.,Ltd.,Qingdao 266000,China;China National Environmental Monitoring Center,Beijing 100012,China;Qingdao Mingde Environmental Protection Instrument Co.,Ltd.,Qingdao 266000,China;Shandong Institute of Metrology,Ji’nan 250014,China;Qingdao Institute of Metrology Technology,Qingdao 266000,China)
出处
《分析仪器》
CAS
2023年第2期68-73,共6页
Analytical Instrumentation
关键词
烟尘颗粒物
Β射线法
重量法
Soot particle
Beta-ray method
Gravimetric method