摘要 通过实验室与现场测试验证了不同行业工况下烟尘颗粒物对基于β射线法烟尘直读仪的数据影响分析,分析了实验室验证数据产生负偏差的原因及解决措施,综合实验室与现场验证数据得出β射线法的烟尘直读仪测量数据不仅准确度高,而且与重量法数据相关性高,说明了β射线法烟尘直读仪不受不同行业工况的烟尘颗粒物影响。 Through laboratory and field tests,the causes of the negative deviation of laboratory verification data are analyzed.The verification data shows that the measurement data of theβ-ray method is not only highly accurate,but also highly correlated with the data using the gravimetric method,indicating that theβ-ray method is not affected by soot particles under different industry conditions.
作者 李金莹 秦承华 田红兵 李德安 高捷 王婷 谢元壮 梅金 Li Jinying;Qin Chenghua;Tian Hongbing;Li De’an;Gao Jie;Wang Ting;Xie Yuanzhuang;Mei Jin(Qingdao Minghua Electronic Instrument Co.,Ltd.,Qingdao 266000,China;China National Environmental Monitoring Center,Beijing 100012,China;Qingdao Mingde Environmental Protection Instrument Co.,Ltd.,Qingdao 266000,China;Shandong Institute of Metrology,Ji’nan 250014,China;Qingdao Institute of Metrology Technology,Qingdao 266000,China)
出处 《分析仪器》 CAS 2023年第2期68-73,共6页 Analytical Instrumentation
关键词 烟尘颗粒物 Β射线法 重量法 Soot particle Beta-ray method Gravimetric method