旨在优化医药洁净厂房电气设计的合理性,以及利于施工、验收,就医药洁净厂房爆炸危险区域划分、供配电设计、照明及应急照明设计等,对因规范理解实施过程中引起的争议或模糊点进行研究、梳理和讨论,以解决其带来的系列疑难或困惑,做到合理统一。
In this paper,the electrical design of the medical clean workshop was reasonably optimized,and conducive to construction and acceptance.On the division of the explosive danger area of the medical clean workshop,power supply and distribution design,lighting and emergency lighting design,the disputes or fuzzy points caused by the understanding and implementation of the code were studied,sorted out and discussed,so as to solve the series of difficulties or puzzles brought by it and achieve reasonable unification.
作者
童涛
邓逍坷
Tong Tao;Deng Xiaoke(Shaanxi Coal Group Shengbang Technology Co.,Ltd.,Shanghai 201210,China)
出处
《化工与医药工程》
2023年第1期21-24,共4页
Chemical and Pharmaceutical Engineering
关键词
医药洁净
爆炸危险区域
变配电室
低压配电
照明
pharmaceutical cleansing
explosion hazard area
substation
low-voltage power distribution
lighting