文章阐述了全站仪自动化监测系统在地铁保护区监测中的技术优势,介绍了盾构隧道自动化监测测点布设原则,实例论述了动态全站仪自动化监测系统在长距离地铁保护监测中的技术方法,总结了提高动态全站仪自动化监测精度的技术措施和方法。
This paper expounds the technical advantages of the total station automatic monitoring system in the monitoring of metro protection area,introduces the layout principle of the automatic monitoring point of shield tunnel,discusses the technical methods of dynamic total station automatic monitoring system in the protection and monitoring of long distance subway with examples,and summarizes the technical measures and methods to improve the accuracy of dynamic total station automatic monitoring system.