期刊文献+

弛放气尾气中氢含量超标原因分析与对策

ANALYSIS ON HIGH HYDROGEN CONTENT IN THE PURGE GAS AND THE COUNTERMEASURES
下载PDF
导出
摘要 介绍ICI-AMV弛放气冷箱工作原理及弛放气尾气中氢含量超标的危害,生产原料气改变对系统氢氮比的影响及冷箱液位长期无液位控制是其尾气中氢含量超标的主要原因。通过技术改造及从工艺和仪表方面控制弛放气尾气中氢含量降低到设计指标以下。 This paper described the working principle of ICI-AMV purge gas cold box and the hazard incurred by high hydrogen content in the purge gas.High hydrogen content was mainly caused by the change of raw material gas that may impact on hydrogen-nitrogen ratio,and the missing of control on cold box liquid level at a long run.By technical reformation and effective control of hydrogen content in the purge gas in the process and the instrument discipline,hydrogen content was controlled within the designed limitation.
作者 曾晓波 吴桂波 陈宣宇 施宏昊 Zeng Xiaobo;Wu Guibo;Chen Xuanyu;Shi Honghao(CNOOC Fudao Co.,Ltd.,Dongfang 572600)
出处 《大氮肥》 CAS 2023年第2期92-95,共4页 Large Scale Nitrogenous Fertilizer Industry
关键词 弛放气 深冷 氢氮比 冷箱 液位控制 回火 purge gas cryogenic hydrogen-nitrogen ratio cold box liquid level control temper
  • 相关文献

参考文献3

二级参考文献3

共引文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部