摘要
针对非线性脉冲负载,分析了非线性脉冲负载的脉冲电流大、瞬时容量大和负载电流波形严重畸变等特性,提出了非线性脉冲负载瞬间电压降落与移动电源发电机参数及容量的关系,通过瞬间电压降落计算及测试对比分析,寻求移动电源发电机所需设计容量及适应非线性脉冲负载的发电机技术。
For nonlinear pulse load,the characteristics of large pulse current,large instantaneous capacity and serious distortion of load current waveform are analyzed.The relationship between transient voltage drop of nonlinear pulse load and generator parameters and capacity of mobile power is proposed.Through transient voltage drop calculation and test comparative analysis,The design capacity of mobile power generator and generator technology adapted to nonlinear pulse load are sought.
作者
徐剑萍
陈正龙
李自力
杨梦
XU Jian-ping;CHEN Zheng-long;LI Zi-li;YANG Meng(Hunan Sany Industrial Technology Career College,Changsha 410129,China;Zhejiang Happiness Aerospace Technology Co.LTD,Huzhou 313005,China)
出处
《移动电源与车辆》
2023年第1期27-30,共4页
Movable Power Station & Vehicle
关键词
非线性脉冲负载
瞬间电压降落
发电机容量
nonlinear pulse load
instantaneous voltage drop
generator capacity