摘要
结合国内某联合循环余热锅炉出现的流动加速腐蚀问题,对现场泄漏的蒸发器管道进行取样检测,分析发生腐蚀的原因,同时探讨预防联合循环余热锅炉发生流动加速腐蚀的措施。
Based on the flow accelerated corrosion of the combined cycle HRSG in a domestic power plant,sampled and tested the leaking evaporator pipe,analyzed the causes of corrosion,and discuss the measures to prevent the flow accelerated corrosion of combined cycle HRSG.
作者
郭大山
张志伟
GUO Dashan;ZHANG Zhiwei(State Key Laboratory of Efficient and Clean Coal-Fired Utility Boilers(Harbin Boiler Company Limited),Harbin 150046,China)
出处
《锅炉制造》
2023年第3期11-13,共3页
Boiler Manufacturing
关键词
余热锅炉
低压蒸发器
流动加速腐蚀
HRSG
Low pressure evaporator
Flow accelerated corrosion