摘要
以逐时冷负荷数据的变异系数作为负荷特性指标,比较了4种典型气候条件下不同冷源配置方案的运行能耗,得到不同气候条件(不同负荷特性)下集中空调系统冷源配置规律,建立了以逐时冷负荷变异系数、冷源小机单机容量占比为变量的冷源配置优化数学模型。
This paper uses the coefficient of variation of hourly cooling load data as the load characteristic index,compares the operating energy consumption of different cold source configuration schemes under four typical climatic conditions,and derives the law of cold source configuration of central air conditioning systems under different climatic conditions(different load characteristics).An optimization mathematical model for the cold source configuration with the hourly cold load variation coefficient and the single unit capacity proportion of small units as variables is established.
作者
翁达福
王建飞
Weng Dafu;Wang Jianfei(Xiamen Panport Integrated Energy Service Co.,Ltd.,Xiamen;Lets Holding Group Co.,Ltd.,Xiamen)
出处
《暖通空调》
2023年第5期118-123,共6页
Heating Ventilating & Air Conditioning
关键词
集中空调
冷源配置
负荷特性
冷负荷变异系数
气候条件
运行能耗
central air conditioning
cold source configuration
load characteristic
cold load variation coefficient
climatic condition
operating energy consumption