期刊文献+

Energy flexibility characteristics of centralized hot water system in university dormitories

原文传递
导出
摘要 The large-scale application of renewable energy is an important strategy to achieve the goal of carbon neutrality in the building sector.Energy flexibility is essential for ensuring balance between energy demand and supply when targeting the maximum penetration rate of renewable energy during the operation of regional integrated energy systems.Revealing the energy flexibility characteristics of centralized hot water systems,which are an important source of such flexibility,is of great significance to the optimal operation of regional integrated energy systems.Hence,in this study,based on the annual real-time monitoring data,the energy flexibility of the centralized hot water system in university dormitories is evaluated from the perspective of available storage capacity(C_(ADR)),recovery time(t_(recovery)),and storage efficiency(η_(ADR)),by the data-driven simulation method.The factors influencing the energy flexibility of the centralized hot water system are also analyzed.Available storage capacity has a strong positive correlation with daily water consumption and a strong negative correlation with daily mean outdoor temperature.These associations indicate that increased water use on the energy flexibility of the centralized hot water system is conducive to optimal dispatching.In contrast,higher outdoor temperature is unfavorable.The hourly mean value of the available storage capacity in spring and winter is found to be around 80 kWh in the daytime,and about twice that in summer and autumn.Recovery time is evenly distributed throughout the year,while t_(recovery)/C_(ADR)in spring and winter is about half that in summer.The storage efficiency was significantly higher in spring,summer,and winter than in autumn.The hourly mean storage efficiency was found to be about 40%in the daytime.The benefits of activating energy flexibility in spring and winter are the best,because these two seasons have higher available storage capacity and storage efficiency,while the benefit of activating energy flexibility is the highest at 6:00 a.m.,and very low from midnight to 3:00 a.m.
出处 《Building Simulation》 SCIE EI CSCD 2023年第4期641-662,共22页 建筑模拟(英文)
基金 This work was funded by the Center for Balance Architecture of Zhejiang University under the project:K Transversal 20203512-24C This study was also partially supported by the Ningbo Science and Technology Bureau(No.2021S141).
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部