期刊文献+

基于氧化石墨烯功能化锥形光纤的血红蛋白传感研究 被引量:1

Study on Hemoglobin Sensing by Graphene Oxide Functionalized Tapered Optical Fiber
原文传递
导出
摘要 通过混沌相关光纤环衰荡传感系统实时监测氧化石墨烯沉积过程,并采用氧化石墨烯功能化锥形光纤作为传感元件对血红蛋白传感进行了实验研究。通过实时监测氧化石墨烯对锥形光纤功能化过程中衰荡时间的变化,分析了功能化过程中锥形光纤表面羟基化、硅烷化和氧化石墨烯沉积对光传输损耗的影响。通过扫描电子显微镜对氧化石墨烯功能化锥形光纤效果进行检测。研究了不同浓度的氧化石墨烯功能化锥形光纤作为传感元件时对血红蛋白传感灵敏度的影响,实验结果表明:与未功能化锥形光纤相比,使用氧化石墨烯功能化锥形光纤进行血红蛋白传感,灵敏度提高了一个数量级。在功能化过程中,氧化石墨烯浓度将影响功能化后锥形光纤的传感灵敏度,且随着浓度的增加传感灵敏度增强。该研究成果有望在生物传感领域得到应用。 In this study,the functionalization of a tapered optical fiber using graphene oxide is monitored in real time by a chaotic correlation fiber loop ringdown system,and hemoglobin sensing is achieved experimentally with the functionalized graphene oxide tapered optical fiber as the sensor element.The functionalization of the tapered optical fiber surface using graphene oxide can be divided into hydroxylation,silanization,and grapheneoxide deposition.The effect of transmission loss is analyzed during functionalization according to the change in the ringdown time.The functionalized tapered optical fiber is tested via scanning electron microscopy.Moreover,the sensitivity of hemoglobin sensing is evaluated using different concentrations of graphene oxide in the functionalization process.The experimental results show that the functionalized tapered optical fiber exhibits a considerable increase in sensitivity by an order of magnitude compared with the unfunctionalized tapered optical fiber.The sensitivity of the functionalized tapered optical fiber is influenced by the concentration of graphene oxide during functionalization;sensitivity increases with concentration.These results can potentially be applied in the field of biosensing.
作者 刘壮 杨玲珍 王娟芬 冯纪鑫 刘娇娇 姜琦 Liu Zhuang;Yang Lingzhen;Wang Juanfen;Feng Jixin;Liu Jiaojiao;Jiang Qi(College of Physics and Optoelectronics,Taiyuan University of Technology,Taiyuan 030024,Shanxi,China;Key Lab of Advanced Transducers and Intelligent Control System,Ministry of Education,Taiyuan University of Technology,Taiyuan 030024,Shanxi,China)
出处 《激光与光电子学进展》 CSCD 北大核心 2023年第5期211-216,共6页 Laser & Optoelectronics Progress
基金 国家自然科学基金(61975141,61575137,61675144)。
关键词 医用光学与生物技术 锥形光纤 氧化石墨烯 光纤环衰荡 血红蛋白 传感 medical optics and biotechnology tapered optical fiber graphene oxide fiber loop ringdown hemoglobin sensing
  • 相关文献

参考文献4

二级参考文献17

  • 1Ellison SLR, Burke S, Walker RF, et al. Uncertainty for reference materials certified by inter-laboratory study : recommendations of an international study group. Accred Qual Assur,2001, 6:274-277.
  • 2Pauwels J, Lamberty A, Schimmel H. Homogeneity testing of reference materials. Accred Qual Assur,1998, 3: 51-55.
  • 3European Commission: DG XⅡ-5-C (SMT Programme ). Guidelines for the production and certification of reference materials, Document BCR/01/97. European Commission, Brussels.
  • 4van Assendelft OW, Buursma A, Zijlstra WG. Stability of haemiglobincyanide standards. J Clin Pathol, 1996, 49: 275- 277.
  • 5Zwart A, van Assendelft OW, Bull BS, et al. Recommendations for reference method for haemoglobinometry in human blood (ICSH standard 1995 ) and specifications for international haemiglobinocyanide standard (4th edition ). J Clin Pathol, 1996,49 : 271-274.
  • 6中华人民共和国国家计量技术规范(JIG1006-94).一级标准物质技术规范.北京:中国计量出版社,1995.
  • 7ISO Guide 35. Reference materials-General and statistical principles for certification. Geneva Switzerland:ISO ,2006.
  • 8NCCLS. H15-A3. Reference and selected procedures for the quantitative determination of hemoglobin in blood. Approved Standard. 3rd ed. Wayne Pa:NCCLS,2000.
  • 9李蓓蓓,薛强,李锦丰,张帆,邹明强,杨屹.新城疫病毒和禽流感病毒复合型胶体金免疫层析试纸条的制备[J].畜牧与兽医,2009,41(8):33-37. 被引量:11
  • 10谭展,廖常锐,刘申,侯茂祥,张哲,郭奎奎,王义平.基于空芯光纤和光纤布拉格光栅的温度应变同时测量传感器[J].光学学报,2018,38(12):90-96. 被引量:21

共引文献24

同被引文献2

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部