摘要
为解决数据中心制冷系统能耗不断提升、余热未被合理利用、含“氟”制冷剂大量使用等问题,本文突破数据中心自身的限制,研究提出结合区域规划,构建基于CO_(2)热泵技术的“数据中心+”能源利用方案,打造以数据中心余热为核心的区域冷热供应系统,充分利用数据中心余热为周边用户提供生活热水或供暖服务,促进数据中心从能源消费者向提供者转变。计算表明,研究所提出的方案具有显著的经济效益和节能降碳效果。
In order to solve the problems in data centers,such as increasing energy consumption of refrigeration system,waste heat not being used rationally,a large number of refrigerants containing“Fluorine”being used,this paper puts forward to construct the“Data Center+”region energy systems based on CO_(2) heat pump.The systems take the data center as the energy producer instead of consumer and provide hot water or heating for the residents.The results show that the proposed scheme has obvious economic benefits,and the effect of energy saving and carbon reduction is significant.
作者
周廷
李晓丹
ZHOU Ting;LI Xiao-dan
关键词
数据中心
CO_(2)热泵
余热利用
节能降碳
data center
CO_(2)heat pump
waste heat utilization
energy saving and carbon reduction